York HVAC Catalogue 2018 EN 2019 EN | Page 157

YORK ® AIR-CONDITIONING PRODUCTS Performance at JOHNSON CONTROLS test conditions* Technical Characteristics YC-OPU: with chilled water coil and up-flow air supply Models 10a 20a 30 50 80 110 160 220 160.3 Performances Total cooling capacity kW 10.1 18.2 32.4 43.6 66.8 80.2 121.9 Sensible cooling capacity kW 9.4 15.7 29.8 38 62 72 110 144 36.07 33.09 27.93 24.36 27.83 28.04 27.09 28.02 EER Airflow m 3 /h 2.200 3.200 7.400 8.200 15.400 17.000 26.000 34.000 Sound pressure level dB(A) 51 57 58 61 60 61 63 64 Lenght mm 750 750 860 860 1.750 1.750 2.640 3.495 Depth mm 601 601 880 880 880 880 880 880 Height mm 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 Net weight kg Dimensions & weight 155 160 220 240 340 360 540 700 Free Cooling ¡ ¡ ¡ l ¡ l l ¡ Two Sources ¡ ¡ ¡ l ¡ l l ¡ * Performance refers to: R410a refrigerant; condensing temperature 45°C; incoming air 24°C-45%Rh; water 7/12°C; external static pressure 30 Pa. The declared performance does not take into account the heat generated by fans, which must be added to the system thermal load. EER (Energy Efficiency Ratio) = total cooling capacity / compressors power consumption + fans power consumption (air cooled condensers excluded). Sound levels at a 2 m distance, in a free field, as per UNI EN ISO 3744:2010. Technical Characteristics YC-UPU: with chilled water coil and down-flow air supply Models 10 20 30 50 80 110 160 220 160.3 Performances Total cooling capacity kW 10.1 19.2 32.4 43.6 66.8 80.2 121.9 Sensible cooling capacity kW 9.4 15.7 29.8 38.1 62.1 72 109.7 144 36.07 33.09 27.93 24.36 27.83 28.04 27.09 28.02 EER Airflow m 3 /h 2.200 3.200 7.400 8.200 15.400 17.000 26.000 34.000 Sound pressure level dB(A) 51 57 58 61 60 61 63 64 Lenght mm 750 750 860 860 1.750 1.750 2.640 3.495 Depth mm 601 601 880 880 880 880 880 880 Height mm 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 Net weight kg Dimensions & weight 155 160 220 240 340 360 540 700 Free Cooling ¡ ¡ ¡ l ¡ l l ¡ Two Sources ¡ ¡ ¡ l ¡ l l ¡ * Performance refers to: R410a refrigerant; condensing temperature 45°C; incoming air 24°C-45%Rh; water 7/12°C; external static pressure 30 Pa. The declared performance does not take into account the heat generated by fans, which must be added to the system thermal load. EER (Energy Efficiency Ratio) = total cooling capacity / compressors power consumption + fans power consumption (air cooled condensers excluded). Sound levels at a 2 m distance, in a free field, as per UNI EN ISO 3744:2010. 157