York HVAC Catalogue 2018 EN 2019 EN | Page 153

YORK ® AIR-CONDITIONING PRODUCTS Focus on Free Cooling High energy saving air conditioning unit Indirect Free Cooling Using renewable energy sources is required to reduce the environmental impact of systems. Our innovative free cooling systems are able to achieve energy savings of over 50% compared to a conventional air conditioner. The indirect FREE COOLING system is characterised by a hybrid unit, consisting of a primary water circuit and a secondary direct expansion or chilled water circuit. The primary water circuit is connected to a dry cooler that uses outside air - a source of renewable energy - to cool water. The secondary circuit on the other hand exploits the mechanical cooling. Free Cooling from renewable sources Using outside air to cool environments is the primary source of energy savings available in temperate climate areas. Optimised operating procedures Depending on the outside air temperatures, three possible operating procedures are possible: Total Free Cooling The unit completely operates in FREE COOLING without triggering mechanical cooling. Mild climate YORK can now offer a range of FREE COOLING close control air conditioning units which ensure high energy savings combined with the efficiency and reliability that distinguish this type of product. Partial Free Cooling In addition to operating the FREE COOLING circuit, mechanical cooling can be triggered for the time strictly necessary to meet the demand for cooling. Intelligent energy saving The high number of hours per year in which FREE COOLING systems can be used ensures that the air conditioning system energy consumption can be reduced by over 50%. This is reflected in an immediate environmental sustainability increase, thanks to a significant reduction in CO2 emissions, and the system operating costs. No Free Cooling Free Cooling operating hours per year Amsterdam Athens Belgrade Berlin Brussels Nbr. hours (1) 5,641 4,491 5,105 5,583 5,545 Percentage (2) 64% 51% 58% 64% 63% Bucharest Budapest Copenhagen Dublin Helsinki Nbr. hours (1) 5,503 5,279 5,861 7,161 5,796 Percentage (2) 63% 60% 67% 82% 71% Istanbul London Madrid Milan Moscow Nbr. hours (1) 4,779 5,575 4,643 5,281 6,046 Percentage (2) 55% 64% 53% 60% 71% Oslo Paris Prague Reykjavik Vienna Nbr. hours (1) 6,202 5,187 5,619 7,743 5,651 Percentage (2) 73% 59% 64% 88% 65% Regulation is completely entrusted to mechanical cooling, excluding the FREE COOLING circuit.cooling. Self-adaptive set-point of the dry cooler In order to maximise the efficiency of the FREE COOLING system, the unit can handle the regulation of the dry cooler coupled to it directly. Thanks to the self-adaptive set-point function, the fan speed can be regulated so that the water always has a temperature consistent with the outside air conditions. This leads to an increase in the system efficiency, allowing you to maximise the performance of both the FREE COOLING circuit and the direct expansion circuit, ensuring low condensing temperatures. In addition, the fans of the dry cooler will partially operate even with high temperatures, thereby increasing the energy savings of the system. (1) Number of hours with temperatures lower than or equal to 18°C. (2) Percentage calculated on a total of 8,760 hours per year. 153