York HVAC Catalogue 2018 EN 2019 EN | Page 150

Electronic expansion valve Control Panel Electronic expansion valves are one of the most recent pieces of equipment that enable us to improve the energy efficiency at partial loads of direct expansion machines. These valves are installed at the inlet of the evaporator, substituting the traditional thermostatic expansion ones: this allows more precise control of the quantity of refrigerant entering the evaporator, and guarantees good capacity regulation, typically between 100% and 50%. Electronic expansion valves also allows control of the amount of overheated gas at the outlet of the evaporator, thus allowing a significant reduction of the condensation pressure during winter or night-time operation whilst maintaining the evaporation pressure unchanged. Adoption of the electronic expansion valve (optional) guarantees a significant increase of the EER values. All the units are equipped with a complete control panel with main isolator switch. Magnetothermic switches, contactors, and all necessary protection is provided, as required by legal codes and standards. The control panel of the units equipped with compressors (“A” as third letter of the identification code) has as standard a phase sequencer, which prevents the compressor from getting damaged when counter running. Also, the control panel has 4 configurable input and output for remote signalling, as well as two terminals for starting up and stopping the unit from remote position. The condenser fan speed controller (accessory) is installed in the unit and controlled with a 0-10V signal from the microprocessor. All the control parameter are managed by the microprocessor. The controller is valid for all the AC 230V motors. One or two completely independent compressors EC fans control and power lines available as alternatives. Models with “1” as the last digit of the unit model number have a single circuit and a single compressor. Those with “2” as the last digit on the other hand have two completely independent refrigerant circuits and two compressors. The circuits are fitted with all the safety and regulation devices necessary for efficient and reliable operation. The evaporator coil can be single or double circuit depending on the number of compressors. Hydraulic circuit Air conditioners with chilled water coil, YC-OPU and YC-UPU, include a finned coil and a three-way motorised valve for water flow regulation. The hydraulic circuit is provided with copper tubes. The coils are optimised for both water with a temperature of 7/12 and for higher ones such as 15/20. Modulating controller display and keypad Modulating regulation of the cooling capacity Large surface filters If a very precise regulation and high response speed are required, a modulating valve is installed as standard. This valve is recommended in case of functionment with a lot of fresh air. The units are equipped with self-extinguishing media class G4 filters. The filters are installed inclined before the cooling coil in order to offer a larger surface and allow lower air crossing speeds, with lower energy consumption. M5 or F7 filters ON COILS available as accessories. Design suitable to civil environments YORK ® YC-P Series air conditioners have a pleasant and functional design, suitable for installation in civil environments. Their structure consists of aluminium profiles and closing panels hinged on them. Both panels and profiles are epossidic painting RAL 7024. Two versions are available for up flow units (YC-OP): front grille & top air discharge (standard), or blind front panel, suction from the bottom and top discharge (optional). 150