York HVAC Catalogue 2018 EN 2019 EN | Page 145

YORK ® AIR-CONDITIONING PRODUCTS YEPR Heat Recovery Units YEPR 1 to 4 Technical features Model Maximum supply and return air flow rate Supply and return rated available static pressure Minimum supply and return air flow rate Thermal efficiency EU regulation 1253/14 (1) Total thermal output recovered (1) Maximum recovery efficiency (2) Total thermal output recovered (2) Total number of fans Rated absorbed electrical power (3) Maximum total absorbed current (3) Unit power supply (3) Protection rating with machine installed Unit weight YEPR 1 720 0.20 170 270 80 3.9 90 6.5 2 330 2.8 230-1 + N / 50Hz IP20 90 m 3 /h m 3 /h Pa m 3 /h % kW % kW - W A V-Ph - kg YEPR 2 1150 0.32 220 300 80 6.2 90 10.5 2 770 3.4 230-1 + N / 50Hz IP20 140 YEPR 3 1700 0.47 250 600 80 9.1 90 15.4 2 1060 4.7 230-1 + N / 50Hz IP20 170 YEPR 4 2600 0.72 250 690 85 14.8 94 24.5 2 1460 6.5 230-1 + N / 50Hz IP20 320 1) Air conditions: EAT = 5°C and t i = 25°C, no condensate 2) Air conditions: EAT = -10°C and t i = 20°C, RHi 50% RH 3) Basic version Overall dimensions of the packaged unit Model Dimensions Weight YEPR 1 YEPR 2 YEPR 3 D mm 469 510 595 YEPR 4 735 E mm 1845 1845 2245 2345 F mm 1030 1030 1430 1880 kg 119 165 198 370 Thermal performances - Internal conditions: ti = 20°C - RHi = 50% Model YEPR 1 YEPR 2 YEPR 3 YEPR 4 Q v m3/h 100 150 300 450 600 750 200 250 500 750 1000 1250 300 400 800 1200 1650 2000 400 550 1100 1700 2300 2900 P h kW 0.30 0.44 0.85 1.25 1.63 2.01 0.60 0.74 1.42 2.08 2.72 3.35 0.89 1.17 2.24 3.27 4.42 5.29 1.28 1.72 3.31 4.98 6.62 8.23 EAT: 10°C Ɛ t m w % kg/h 90.4 0.00 88.2 0.00 84.6 0.00 82.6 0.00 81.2 0.00 80.1 0.00 89.4 0.00 88.2 0.00 84.6 0.00 82.5 0.00 81.1 0.00 80.0 0.00 88.4 0.00 86.9 0.00 83.4 0.00 81.4 0.00 79.8 0.00 78.9 0.00 95.3 0.00 93.5 0.00 89.7 0.00 87.4 0.00 85.8 0.00 84.6 0.00 t i = Internal air temperature RH i = Internal relative humidity EAT = External air temperature Q v = Intake air flow rate Q r = Return air flow rate P h = Thermal recovery on the intake flow P h kW 0.46 0.67 1.28 1.87 2.45 3.03 0.90 1.11 2.13 3.12 4.08 5.04 1.34 1.75 3.36 4.92 6.63 7.95 1.92 2.59 4.97 7.48 9.94 12.36 EAT: 5°C Ɛ t % 90.5 88.3 84.7 82.7 81.3 80.2 89.5 88.3 84.7 82.6 81.2 80.1 88.5 87.0 83.5 81.5 79.9 79.0 95.4 93.6 89.8 87.5 85.9 84.7 m w kg/h 0.15 0.21 0.42 0.62 0.81 0.96 0.29 0.36 0.69 1.04 1.35 1.68 0.43 0.56 1.10 1.64 2.20 2.53 0.63 0.84 1.61 2.45 3.22 4.02 P h kW 0.62 0.90 1.74 2.55 3.35 4.13 1.22 1.50 2.90 4.25 5.57 6.88 1.81 2.38 4.57 6.71 9.06 10.87 2.58 3.49 6.72 10.14 13.50 16.81 EAT: 0°C Ɛ t % 91.7 89.8 86.4 84.5 83.2 82.2 90.8 89.7 86.4 84.5 83.1 82.1 89.9 88.5 85.2 83.4 81.9 81.0 96.1 94.5 91.1 89.0 87.5 86.4 Ɛ t = Recovery efficiency with balanced flow rates m w = Condensate production b = Unbalance percentage Ɛ t * = Recovery efficiency with unbalanced flow rates F T = Correction coefficient according to EAT variation F Q = Correction coefficient according to Qv variation 145 m w kg/h 0.26 0.38 0.72 1.09 1.43 1.71 0.51 0.63 1.20 1.81 2.38 2.85 0.76 1.00 1.91 2.88 3.88 4.54 1.10 1.49 2.82 4.34 5.77 6.97 P h kW 0.79 1.17 2.26 3.34 4.39 5.43 1.57 1.94 3.77 5.56 7.31 9.04 2.34 3.08 5.97 8.79 11.91 14.31 3.27 4.44 8.65 13.13 17.53 21.88 EAT: -5°C Ɛ t m w % kg/h 94.3 0.36 92.7 0.53 90.0 1.03 88.4 1.52 87.3 2.01 86.4 2.43 93.5 0.70 92.7 0.88 90.0 1.72 88.4 2.52 87.2 3.35 86.3 4.05 92.9 1.06 91.8 1.37 89.0 2.66 87.4 3.90 86.1 5.31 85.4 6.49 97.5 1.50 96.4 1.98 93.8 3.89 92.1 5.87 90.9 7.90 90.0 9.99 2980 P h Q v (t i - TAE) b = Q r / Q v Ɛ t * = Ɛ t b F r F Q Ɛ t = P h kW 0.97 1.44 2.81 4.16 5.49 6.80 1.93 2.40 4.69 6.93 9.14 11.32 2.88 3.81 7.44 10.99 14.92 17.95 3.97 5.42 10.64 16.23 21.74 27.19 EAT: -10°C Ɛ t % 96.5 95.4 93.2 91.9 90.9 90.1 96.0 95.3 93.2 91.8 90.8 90.0 95.5 94.6 92.4 91.0 89.9 89.2 98.7 98.0 96.1 94.9 93.9 93.2 m w kg/h 0.44 0.65 1.25 1.85 2.47 3.01 0.86 1.08 2.08 3.09 4.12 5.00 1.31 1.69 3.36 4.97 6.57 8.05 1.75 2.43 4.74 7.25 9.83 12.09