YORK ® AIR-CONDITIONING PRODUCTS
Options / Accessories
Compatibility table / Codes
Model
LASER
Sizes
LOW BODY
110 112 114 216 218 220 222 224 226 328
l l l l l l l l l l
l l l l l l l l l l
110 112 114 216 218
l l l l l
l l l l l
With Cabinet
YLV-YLH
YLV-YLH/AF Front air intake
YLVR
2/3/4 rows
2/3/4 rows
2/3 rows
Without Cabinet
YLIV-YLIH
YLIV-YLIH/AF Front air intake
YLIVR
2/3/4 rows
2/3/4 rows
2/3 rows
l l l l l l l l l l
l l l l l l l l l l
Options (Factory fitted)
Coil and heaters
1 row heating
Kit electrical heater (with relay and safety switch)
BA1
KREL
l l l l l l l l l l l l l l l
l l l l l l l l l l l l l l l
Built in thermostat
Fan speed selector
Thermostat with manual fan speed
and S/W change over
Thermostat with manual fan speed,
dead band, automatic change over
Thermostat with automatic fan speed,
dead band, automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valve
Parallel connection CSL00 l
CML00 l
CEL00 l
CEL20 l
CEL30 l
For ON/OFF valve one/FCU
For modulating valve one/FCU CBL20
CBL30
l
l
3 way valve factory fitted
For 2 pipe systems ON/OFF
For 4 pipe systems ON/OFF
J3A2 (2p)
J3A2 (4p)
l
l
3 way modulating valve factory fitted
For 2 pipe systems Modulating
For 4 pipe systems Modulating
J3AM (2p)
J3AM (4p)
l
l
Shut off valves factory fitted
For 2 pipe systems
For 4 pipe systems
Condensate pump
WS sensor change over for CEL/CER
Minimum temperature thermostat
DT (2p)
DT (4p)
PC
WS
TM
l
l
l
l
l
Accessories (Supplied loose)
Remote controllers and thermostat (wall mounted)
Fan speed selector
Thermostat with manual fan speed
and S/W change over
Thermostat with manual fan speed,
dead band, automatic change over
Thermostat with automatic fan speed,
dead band, automatic change over
Thermostat with automatic fan speed, dead band,
automatic change over for modulating valve
Feet and panel (1) CSR00 l
CMR00 l
CER00 l
CER20 l
CER30 l
Set of painted feet
Set of painted feet + frontal socle
Vertical painted back panel
Horizontal painted back panel CP1
ZL1
PPV1
PPH1 l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
Plenums and air intake (1)
Air intake plenum
Air intake plenum with collars
90° air intake plenum
Air intake duct fitting
Air delivery plenum with collars
90° air delivery plenum
PA
PAS
PA90
RCA
PM
PM90
(1) for check compatibility with the models of FCU see compatibility table
121