York HVAC Catalogue 2018 EN 2019 EN | Page 41

YORK ® AIR-CONDITIONING PRODUCTS Air-cooled VSD screw chiller with integrated Free-cooling YVFA Saving energy is simple in every situation Condenser 1 Condenser Cooling Coil Condenser Closed-loop Configuration Flash Tank (optional) Closed Glycol Loop Compressor with Unit Mounted Pump Flash Tank Free Cooling Coil Condenser Open-loop Configuration Brazed Plate Heat Exchanger Flash Tank Free Cooling Coil Condenser Free Cooling Condenser Coil Compressor Evaporator Automatic Liquid Control Valve Compressor Evaporator Flash Tank Automatic Liquid Control Valve Condenser 2 Cooling Coil Free Cooling Condenser Coil Flash Tank Free Cooling Coil Condenser Closed-loop Configuration Flash Tank (optional) Closed Glycol Loop with Unit Mounted Compressor Pump Evaporator Automatic Liquid Open-loop Configuration Control Valve Brazed Plate Heat Exchanger Compressor Free Condenser Cooling Coil Evaporator Flash Tank Automatic Liquid Control Valve Compressor Flash Tank Free Cooling Condenser Coil Evaporator Automatic Liquid Control Valve Condenser 3 Free Compressor Cooling Flash Tank Free Cooling Coil Free Cooling Coil Automatic Liquid Control Valve Hybrid Cooling Mode When ambient temperatures permit, liquid flow through the free-cooling coils is enabled. This pre-cooling reduces energy use while the compressors deliver final cooling to meet setpoint. Thanks to YORK ® VSD Screw technology, at reduced ambient the compressors may draw less power than the fan motors required to move air through the free-cooling coils. Advanced controls provide the most efficient operation rather than simply shutting off compressors as quickly as possible. The Annual Energy Cost Report demonstrates the benefit of this intelligent control. Compressor Free Evaporator Flash Tank Automatic Liquid Control Valve Mechanical Cooling Mode When it’s too warm to use ambient air for cooling, the YVFA performs as a standard chiller. The automatic flow-control valve in the open-loop configuration bypasses the free- cooling coils to reduce pump energy. When either cooling load or ambient temperature are less than full design condition, the variable- speed screw compressors and condenser fans modulate to optimize energy use. In a closed- loop configuration, the free-cooling coils are also bypassed. Compressor Free Coil Evaporator Closed Glycol Loop LD19976c with Unit Mounted Pump Flash Tank Closed-loop Configuration (optional) Evaporator Flash Tank Automatic Liquid Open-loop Configuration Control Valve Brazed Plate LD19976c Heat Exchanger Evaporator Automatic Liquid Control Valve LD19976c Manufacturer reserves the rights to change specifications without prior notice. 41 Free Cooling Mode At lower ambient temperatures, full cooling load can be most efficiently delivered by the free-cooling coils. Compressors are shut off and the VSD fans are modulated to meet the cooling setpoint.