York HVAC Catalogue 2018 EN 2018 | Page 16
YORK ® AIR-CONDITIONING PRODUCTS
Air to water scroll heat pump
YLHD 0040 to 0150
Technical features
Models
Compressor
Air side
heat
exchanger
Water side
heat
exchanger
Dimensions
& Weight
El. supply
Cooling capacity (1)
kW
Heating capacity (1)
kW
Total Input Power cool/heat mode (1) kW
EER / COP (1)
SCOP
ŋs, h
Capacity steps
%
Sound power level
dB(A)
Type
Quantity
Fans quantity
Nominal air flow
m 3 /h
Nominal static pressure
Pa
Working ambient temp. cool. / heat. mode
Type
Unit water volume
Litres
Pump Type
Nominal water flow
l/h
Available pressure (1) (2)
kPa
Pressure drop (1) (3)
kPa
Working range water leaving
temperature cooling / heating (5)
Water connections
inch
Height
mm
Width
mm
Depth
mm
Weight without pack / pack
kg
Voltage / Phases / Frequency
V/ph/hz
T Three phases supply P Hydro Pack H Heat pump
0040 T-TP
39.8
43.2
15.13 / 15.6
2.63 / 2.77
3.3
129
0070 T-TP
67.5
72.5
26.57 / 26.46
2.54 / 2.74
3.38
136
YLHD
0100 T-TP
95.4
104.6
36.27 / 37.63
2.63 / 2.78
3.7
145
50-100
83
86
2
2
2
2
18 000
23 000
100
150
(4) (-18°C) ~ 46°C / -10°C ~ 20°C
Single plate heat exchanger
84
92
6 880
105
31
12 040
120
53
86
Scroll
4
4
0120 T-TP
116.5
120.1
42.21 / 43.2
2.76 / 2.78
3.57
140
25-50-75-100
86 0150 T-TP
142.5
159.5
60.13 / 59.07
2.37 / 2.7
3.42
134
4
4 4
4
48 000
36 000
200
-18°C ~ 46°C / -10°C ~ 20°C
Dual plate heat exchanger
193
195
Multistage horizontal pump
17 030
20 470
187
202
54
32
87
214
24 940
186
24.5
-5°C ~ 15°C / 30°C ~ 50°C
2”
1 794
2 659
897
750 / 790
1 794
2 659
897
760 / 800
2 460
3 466
1 101
1 284 / 1 380
400 / 3 / 50 + N + E
2-1/2”
2 460
3 416
1 101
1 284 / 1 380
(1) net values at Eurovent nominal conditions (2) version P with hydro kit with filter (3) version without hydro kit (4) -18°C with LAK option
Nominal conditions: Cooling capacities in kW given for 7°C water leaving temperature ∆t 5°C and 35°C ambient temperature.
Heating capacities in kW given for 45°C water leaving temperature and 7°C ambient temperature.
SCOP calculated according to EN14511 and EN14825. For other Ecodesign calculations, please contact your JCI representative.
ηs calculated according to Ecodesign regulation for heating (813/2013).
2 480
3 768
1 101
1 700 / 1 796
(5) below 6°C with glycol
Compatibility table / Codes
Models
0040 T
Heat pump unit YLHD
S668574083
Models
0040 TP
Heat pump unit YLHD
S668574080
Use this unit code when a factory fitted option is NOT required
Accessories (Supplied loose)
AVM mounting
Flow switch
Remote control
Remote terminal
Cable for remote connection of the terminal
B.M.S. Communication
Models
Heat pump unit YLHD
Models
Heat pump unit YLHD
Use this unit code when a factory fitted option is required
Options (Factory fitted)
Low noise
Dual pump
Coil guard net
Low Ambient Kit
Soft start
Vertical air discharge
Copper/copper condenser
0070 T
S668577083
0070 TP
S668577080
S613029002
0100 T
S668571083
0100 TP
S668571080
0120 T
S668571283
0120 TP
S668571280
S613028180
0150 T
S668571583
0150 TP
S668571580
S613021580
S611992021
S613802011
S613802231
-
S613802041
-
S613802241
S613802051
0040 T
S668000266
0040 TP
S668000267 0070 T
S668000270
0070 TP
S668000271 0100 T
S668000274
0100 TP
S668000275 0120 T
S668000278
0120 TP
S668000279 0150 T
S668000282
0150 TP
S668000283
S613990550
NA NA
NA S613991050
S613991040 S613991285
S613991286 S613991584
S613991585
S613995094
Standard
S613111084
S606744693
S612828205
S613995093
Standard
S606744694
Standard
Contact Johnson Controls
Manufacturer reserves the rights to change specifications without prior notice.
17