York HVAC Catalogue 2018 EN 2018 | Page 16

YORK ® AIR-CONDITIONING PRODUCTS Air to water scroll heat pump YLHD 0040 to 0150 Technical features Models Compressor Air side heat exchanger Water side heat exchanger Dimensions & Weight El. supply Cooling capacity (1) kW Heating capacity (1) kW Total Input Power cool/heat mode (1) kW EER / COP (1) SCOP ŋs, h Capacity steps % Sound power level dB(A) Type Quantity Fans quantity Nominal air flow m 3 /h Nominal static pressure Pa Working ambient temp. cool. / heat. mode Type Unit water volume Litres Pump Type Nominal water flow l/h Available pressure (1) (2) kPa Pressure drop (1) (3) kPa Working range water leaving temperature cooling / heating (5) Water connections inch Height mm Width mm Depth mm Weight without pack / pack kg Voltage / Phases / Frequency V/ph/hz T Three phases supply P Hydro Pack H Heat pump 0040 T-TP 39.8 43.2 15.13 / 15.6 2.63 / 2.77 3.3 129 0070 T-TP 67.5 72.5 26.57 / 26.46 2.54 / 2.74 3.38 136 YLHD 0100 T-TP 95.4 104.6 36.27 / 37.63 2.63 / 2.78 3.7 145 50-100 83 86 2 2 2 2 18 000 23 000 100 150 (4) (-18°C) ~ 46°C / -10°C ~ 20°C Single plate heat exchanger 84 92 6 880 105 31 12 040 120 53 86 Scroll 4 4 0120 T-TP 116.5 120.1 42.21 / 43.2 2.76 / 2.78 3.57 140 25-50-75-100 86 0150 T-TP 142.5 159.5 60.13 / 59.07 2.37 / 2.7 3.42 134 4 4 4 4 48 000 36 000 200 -18°C ~ 46°C / -10°C ~ 20°C Dual plate heat exchanger 193 195 Multistage horizontal pump 17 030 20 470 187 202 54 32 87 214 24 940 186 24.5 -5°C ~ 15°C / 30°C ~ 50°C 2” 1 794 2 659 897 750 / 790 1 794 2 659 897 760 / 800 2 460 3 466 1 101 1 284 / 1 380 400 / 3 / 50 + N + E 2-1/2” 2 460 3 416 1 101 1 284 / 1 380 (1) net values at Eurovent nominal conditions (2) version P with hydro kit with filter (3) version without hydro kit (4) -18°C with LAK option Nominal conditions: Cooling capacities in kW given for 7°C water leaving temperature ∆t 5°C and 35°C ambient temperature. Heating capacities in kW given for 45°C water leaving temperature and 7°C ambient temperature. SCOP calculated according to EN14511 and EN14825. For other Ecodesign calculations, please contact your JCI representative. ηs calculated according to Ecodesign regulation for heating (813/2013). 2 480 3 768 1 101 1 700 / 1 796 (5) below 6°C with glycol Compatibility table / Codes Models 0040 T Heat pump unit YLHD S668574083 Models 0040 TP Heat pump unit YLHD S668574080 Use this unit code when a factory fitted option is NOT required Accessories (Supplied loose) AVM mounting Flow switch Remote control Remote terminal Cable for remote connection of the terminal B.M.S. Communication Models Heat pump unit YLHD Models Heat pump unit YLHD Use this unit code when a factory fitted option is required Options (Factory fitted) Low noise Dual pump Coil guard net Low Ambient Kit Soft start Vertical air discharge Copper/copper condenser 0070 T S668577083 0070 TP S668577080 S613029002 0100 T S668571083 0100 TP S668571080 0120 T S668571283 0120 TP S668571280 S613028180 0150 T S668571583 0150 TP S668571580 S613021580 S611992021 S613802011 S613802231 - S613802041 - S613802241 S613802051 0040 T S668000266 0040 TP S668000267 0070 T S668000270 0070 TP S668000271 0100 T S668000274 0100 TP S668000275 0120 T S668000278 0120 TP S668000279 0150 T S668000282 0150 TP S668000283 S613990550 NA NA NA S613991050 S613991040 S613991285 S613991286 S613991584 S613991585 S613995094 Standard S613111084 S606744693 S612828205 S613995093 Standard S606744694 Standard Contact Johnson Controls Manufacturer reserves the rights to change specifications without prior notice. 17