York HVAC Catalogue 2018 EN 2018 | Page 12

YORK ® AIR-CONDITIONING PRODUCTS Air cooled Scroll DC Inverter chiller and heat pump YMAA 045 to 260 / YMPA 045 to 260 Technical features YMAA / YMPA Model 45 65 80 100 130 160* 200* 230* 260* 44 60 77 99 122 164 189 219 255 EER 2.87 2.78 3.08 2.99 2.94 3 3 3 3 SEER 4.30 4.21 4.35 4.37 4.33 ηs,c 169 166 171 172 170 Cooling capacity c/o units Performance Refrigerant kW Cooling capacity h/p units kW 44 60 77 99 122 164 189 219 255 Heating capacity h/p units kW 50 61 88 100 132 167 190 232 256 COP 3.03 3.04 3.27 3.18 2.98 3,04 2,99 3,03 2,98 SCOP 3.32 3.28 3.39 3.36 3.31 130 128 133 131 129 % Sound power level STD / LN dB(A) 80/75 82/77 81/77 83/79 84/80 87/81 89/82 91/84 Refrigerant circuits # 1 1 2 2 2 3 3 4 4 Refrigerant (R410A) charge kg 9.5 12.3 17.6 20.5 22.8 29.5 32 43.3 46 5 6 7 8 3 3 4 4 27 29 32 34 % Stepless (Inverter) 2 2 3 3 4 EC motor Fan motor type Fans quantity Air side heat exchanger Working ambient temp. cooling mode 1 1 2 2 2 -18 ~ 48°C Working ambient temp. heat. mode -15 ~ 25°C Type Plate Heat Exchanger Unit water volume (w/o pump kit) l 9 10 11 Pump Type 14 15 Variable Speed Drive Pump Nominal water flow l/s 2.1 2.9 3.7 4.7 5.8 7.4 9.1 10.5 11.9 Pressure drop kPa 25 24 23 30 38 23 29 41 38 2235 2316 Working range water leaving temp. cooling -8 ~ 20°C Working range water leaving temp. heating Dimensions & Weight 92/85 DC Scroll Inverter + Scroll Capacity steps Quantity Water side heat exchanger Meet Ecodesign Regulations ηs,h Type Compressor Meet Ecodesign Regulations 25 ~ 55°C Height (w/o pump kit) mm 2440 Width (w/o pump kit) mm 1200 Depth (w/o pump kit) mm Operating weight (w/o pump kit) kg 2500 3050 1500 575 2240 598 875 901 979 1922 2003 YMAA: Cooling only units models. YMPA: Air to water heat pump models. * models with preliminary info. Net values at Eurovent nominal conditions: Cooling capacities in kW given for 7°C water leaving temperature ∆t 5°C and 35°C ambient temperature Heating capacities in kW given for 45°C water leaving temperature and 7°C ambient temperature SEER and SCOP calculated according to EN14511 and EN14825 ηs calculated according to Ecodesign regulation for chillers comfort cooling and heating (813/2013, 2016/2281) For other Ecodesign calculations, please contact your JCI representative. The above data is based on Johnson Control’s selection software YORKworks 17.06. Please refer to the latest version of the software for specific projects Advanced Control Made Easy To help maximize efficiency and keep you in control, the YORK ® Amichi™ Series comes standard with integrated Smart Equipment. This technology allows the equipment to connect seamlessly to building controls like our world-class Verasys™ system, where smart-enabled equipment can self-identify and interoperate. PLUG & PLAY EXPERIENCE Remote Access via Internet Verasys ™ Smart Building Hub Smart Air Handling Unit Manufacturer reserves the rights to change specifications without prior notice. 13 Smart Chiller/Heat Pump Verasys ™ Zone Controller Smart Fan Coil Unit Room Module