x CCP_REVIT Full Combined CCPs | Page 510

Family Creation 4 & Shared Parameters iii. Name = Panel Delta X jjj. Discipline = Common kkk. Type of Parameter = Length lll. Grouping = Other mmm. Type/Instance = Type cccc. Name = Open Percentage dddd. Discipline = Common eeee. Type of Parameter = Integer ffff. Grouping = Other gggg. Type/Instance = Type Insert the following formulae for each parameter: - - - - - - - - - In the formula column for Panel Delta X insert (Panel Width * Opp Ratio) + Edge Offset In the formula column for Edge Offset insert 40 mm * Adj Ratio L In the formula column for Door Panel Angle insert 90° * Open Percentage / 100 In the formula column for Angle C insert 90° - Door Panel Angle In the formula column for Array End insert if(Odd, Panel Delta X * (Door Count - 1), Panel Delta X * Door Count) In the formula column for Opp Ratio insert cos(Panel Angle) In the formula column for Adj Ratio L insert cos(180° - (Door Panel Angle + 90°)) In the formula column for Adj Ratio insert cos(Door Panel Angle) In the formula column for Show Open insert not(Show Closed) 74. Flex the model to check constraints. Tel : 086 166 3362 Fax : 086 567 2315 e-mail : [email protected] Physical Address : 5 Pont Road, Bryanston, Johannesburg Page 27 of 27