Family Creation 4 & Shared Parameters
iii. Name = Panel Delta X
jjj. Discipline = Common
kkk. Type of Parameter =
Length
lll. Grouping = Other
mmm.
Type/Instance
= Type
cccc.
Name = Open
Percentage
dddd.
Discipline =
Common
eeee.
Type of
Parameter = Integer
ffff. Grouping = Other
gggg.
Type/Instance
= Type
Insert the following formulae
for each parameter:
-
-
-
-
-
-
-
-
-
In the formula column for Panel Delta X insert (Panel Width *
Opp Ratio) + Edge Offset
In the formula column for Edge Offset insert 40 mm * Adj
Ratio L
In the formula column for Door Panel Angle insert 90° * Open
Percentage / 100
In the formula column for Angle C insert 90° - Door Panel
Angle
In the formula column for Array End insert if(Odd, Panel Delta
X * (Door Count - 1), Panel Delta X * Door Count)
In the formula column for Opp Ratio insert cos(Panel Angle)
In the formula column for Adj Ratio L insert cos(180° - (Door
Panel Angle + 90°))
In the formula column for Adj Ratio insert cos(Door Panel
Angle)
In the formula column for Show Open insert not(Show
Closed)
74. Flex the model to check
constraints.
Tel : 086 166 3362
Fax : 086 567 2315 e-mail : [email protected]
Physical Address : 5 Pont Road, Bryanston, Johannesburg
Page 27 of 27