x CCP_REVIT Full Combined CCPs | Page 316

Door Schedules REVIT CCP WORKSHOP 11 – DOOR SCHEDULES INSTRUCTOR: DOOR TAGS With regards to door schedules we often need to include more information than the current parameters afforded to us for the doors category. This can be done in one of two ways, either by using project parameters or shared parameters. At this point we need to determine how we will be using these parameters. If they need only appear in a schedule, a project parameter will suffice. However if the information needs to appear in a tag, we will need to use a shared parameter. The reason for this is that the parameter needs to be loaded into both the family and the project In the door tag family, create a new label (located on the Text Panel of the Create Tab), in the type selector edit the label as required (Font Colour, type, size, would factor is etc). Place the label where required and the Edit Label pop-up will appear. This pop-up is divided into two parts, the left shows all the available parameters for the category (in this case Doors), and the right shows the parameters we selected for label. Tel : 086 166 3362 Fax : 086 567 2315 e-mail : [email protected] Physical Address : 5 Pont Road, Bryanston, Johannesburg Page 1 of 11