Family Creation 2 (parametric Arrays) Inside the Family Types Dialogue window. Click on the button under Parameter ‘Add’. The Parameter Properties dialogue window opens up. We will call this parameter ‘Door Number’. It will be an ‘Integer’ Type of Parameter. We will leave it as a ‘Type’ parameter because we want this to apply for all the Cupboards that are placed. You can ‘Group’ the parameter anywhere you like, but for this exercise we can group it under the ‘Construction’. This will also make it easier to change the number of doors when we edit the cupboard inside the project. Door Number will drive Array Number; the formula that will make this work needs to be inserted into the Array Number row. if(Door Number < 2 , 2, Door Number) The formula is as follows; If, the Door Number is less than 2 make it 2 otherwise make it Door Number This translates into: As you can see. The number 1 is inserted into the Door Number field; Array Number stays 2 and will not become less than 2. If any number higher than 2 is inserted into the Door Number field then this number will fill-in for Array Number. Tel : 086 166 3362 Fax : 086 567 2315 e-mail : [email protected] Physical Address : 5 Pont Road, Bryanston, Johannesburg Page 31 of 50