x CCP_REVIT Full Combined CCPs | Page 411

Rendering Dimension from the left side of the ceiling bulkhead to the first vertical reference plane, and then to the right side of the ceiling bulkhead. Click on the “EQ” sign located to the top of the dimension string to equilize and center the reference plane in relation to the ceiling bulkhead sides Dimension and equalise all ceiling bulkhead reference planes as per the image to the right After all dimensions have been placed, select those dimensions and delete the annotations from your drawing. When prompted with a warning dialogue box, press the “OK” button. By pressing the “OK” button, you will only delete the dimension, but not unconstrain the reference lines’ relationships to the sides of the bulkhead ceiling Add equi-distant dimensions as per the previous step to all reference lines, as per the image to the right Tel : 086 166 3362 Fax : 086 567 2315 e-mail : [email protected] Physical Address : 5 Pont Road, Bryanston, Johannesburg Page 11 of 29