Vet Lines MSDS Comfortis Chewable Tablets 140 mg, 270 mg, 560 mg, | Page 3

Page 3 of 5
Section 5 - Fire Fighting Measures
Flash Point :
Not applicable .
Lower Explosion Limit :
No data available .
Upper Explosion Limit :
No data available .
Suitable extinguishing
Water , carbon dioxide , dry chemical .
media :
Hazards from combustion products :
May produce irritating , toxic or asphyxiating gases in fire .
Precautions for fire fighters :
HAZCHEM code :
Wear positive-pressure , self-contained breathing apparatus ( SCBA ) and protective fire-fighting clothing ( including firefighting helmet , coat , pants , boots , and gloves ). If protective equipment is not available or not used , fight fire from a protected location or safe distance .
2X
Section 6 - Accidental Release Measures
Emergency Procedures :
Prevent spilt material from entering drains , sewers , ponds , lakes , streams or other watercourses . Sweep or vacuum material with appropriate dust collection filter in place . Wear protective equipment , including eye protection , to avoid exposure . Collect recovered material in labelled containers for disposal in accordance with local regulations .
Section 7 - Handling and Storage
Requirements for storage areas and containers :
Store below 25 ° C in original container and protect from light .
Section 8 - Exposure Controls / Personal Protection
Exposure Guideline :
Spinosad : Manufacturer recommends TWA 0.3 mg / m ³.
In a manufacturing setting , Engineering measures : Laboratory fume hood or local exhaust ventilation . Product use , natural ventilation normally adequate .
Personal protective equipment ( manufacturing setting ): Respiratory protection : Use an approved respirator fitted with a dust cartridge . Eye protection : Safety glasses or face shield . Skin and body protection : In manufacturing environment , wear chemical resistant gloves when handling product .