Vendor Door Catalogs Neuma Brochure 2019 | Page 76

Hinged Impact
Full Lite- Impact & Cycle Testing Performance
Hinged Patio Doors- Impact & Cycle Testing Performance
s
Product
Max. Testing Dimension
Design Pressure Rating
Structure Performance( psf)
Water Resistance( PSF)
Air
Test Standard
Inswing SLPS( OXXO) 11’ 11” X 6’ 11” DP50 + 75 /-75
7.5
0.03
ASTM E1886 / ASTM E1996
Outswing SLPS( OXXO) 11’ 11” X 6’ 11”
DP50 + 75 /-75
DP70 + 105 /-105
7.5
10.5
0.01
ASTM E1886 / ASTM E1996
Outswing SLP( OXX) 9’ 1” X 6’ 11” DP70 + 105 /-105
10.5
0.003
TAS201 / 202 / 203
Inswing SLPS( OXXO) 11’ 11” X 8’ 0” DP50 Structural Only + 75 /-75
2.9
0.002
ASTM E1886 / ASTM E1996
Inswing SLP( OXX) 9’ 1” X 8’ 0”
DP50 Structural Only
+ 75 /-75
3.75
0.12
TAS201 / 202 / 203
Outswing SLPS( OXXO) 11’ 11” X 8’ 0”
DP50
DP70
+ 75 /-75
7.5
+ 105 /-105 10.5
0.003
ASTM E1886 / ASTM E1996
Outswing SLP( OXX) 9’ 1” X 8’ 0” DP50 + 75 /-75
7.5
0.01
TAS201 / 202 / 203
Outswing SLPL( OXXO) 12’ 1” X 8’ 0” DP70 + 105 /-105
10.5
0.002
TAS201 / 202 / 203
3 / 4 Lite- Impact & Cycle Testing Performance
Hinged Patio Doors
Product s
Max. Testing Dimension
Design Pressure Rating
Structure Performance( psf)
Water Resistance( PSF)
Air
Test Standard
Inswing SLP( OXX) 8’ 10” X 8’ 0” DP50 Structural Only + 75 /-75
3.75
0.003
ASTM E1886 / ASTM E1996
Outswing SLP( OXX) 8’ 10” X 8’ 0” DP50 + 75 /-75
7.5
0.001
ASTM E1886 / ASTM E1996
Outswing SLPS( OXXO) 11’ 11” X 6’ 8” DP50 + 75 /-75
7.5
0.001
ASTM E1886 / ASTM E1996
Inswing SLPS( OXXO) 11’ 11” X 6’ 11” DP50 + 75 /-75
7.5
0.1
ASTM E1886 / ASTM E1996
Energy Performance Rating- Impact Hinged
Door Type
Hinged Impact
Energy Star Climate Zones Door Style Glass Type North North Central South South Central U-Factor SHGC VT
Full Lite
3 / 4 Lite
LoE 3 366
*
*
*
*
0.24
0.13
0.30
LoE 3 340
*
*
*
*
0.24
0.09
0.18
LoE 3 366
*
*
*
*
0.29
0.09
0.20
Sound Transmission Class- Impact Hinged
Product Specification STC
OITC
3080, L Outswing
( 1 " Double Laminated Glass)
35
30
6068, LP Inswing
( 1 " Standard Impact Glass)
34
30
6068, LP Outswing
( 1 " Standard Impact Glass)
34
30
** For Florida Building Code Approval, please see: http:// www. floridabuilding. org / pr / pr _ app _ srch. aspx. For Texas Department of Insurance Approval, see: http:// www. tdi. state. tx. us / wind / prod / indexdr. html. For Dade County Approval, see: http:// www. miamidade. gov / building / pc-search _ app. asp?
Products 39