STEP 6
6A
STEP 7
lock in the market that
allows users to maintain
accreditation on existing PAS
24 doors, without needing
to fit exactly the same
lock as was supplied with
the door. PAS 3621 is now
specified as the benchmark
standard for multipoint locks
in The Building Regulations’
Approved Document Q,
mirroring the BS 3621
standard for locks fitted to
external wooden doors. This
gives a distinct advantage
to trade professionals, as a
suitable replacement can be
fitted on an initial visit from a
small range of van stock, as
opposed to ordering a lock
and repeating the visit at a
later date to complete the
installation.
The step by step
illustrations show the Yale
Doormaster™ Professional
being installed. Designed
with the professional installer
in mind, this lock includes
flexible ‘crop and mate’
technology, which maximises
the scope of installation.
‘Yale’s
Doormaster™ range
of replacement
multipoint locks
allows locksmiths
to offer a ready
solution’
For comprehensive
installation on the full range,
please refer to the fitting
instructions or visit
www.yale.co.uk
LOCKSMITHJOURNAL.CO.UK | MAY/JUN 2016
STEP 1 - Identify what
tools are required and
check that all parts of
the Yale Doormaster™
Professional are
present and correct.
STEP 2 - Remove
all parts of the original
lock - handle, cylinder,
locking mechanism and
keep.
STEP 3 - Lay the
original lock alongside
the Doormaster™
Professional to compare
and check suitability.
STEP 4 - Measure
and cut to fit the
existing door. The
flexible ‘crop and mate’
design enables you
to simply cut the lock
to length and position
gearboxes to match the
locks being replaced.
STEP 5 - When fitting
the new lock start by
positioning the central
gearbox into the centre
aperture, then replace
the euro cylinder and
handles.
STEP 6 - Mark and
fit the center keep of
the 3-piece keep and
Uni-Packer™ system.
For PVCu doors the
preassembled patented
Uni-Packer™ allows for
fast, easy and reliable
installation.
STEP 7 - Place the
top hook gearbox into
position in the top
aperture, check the
top hook operates
correctly, then mark and
place the top keep into
position.
STEP 8 - Repeat
for the bottom hook
gearbox unit and bottom
keep and set level of
compression required.
The Yale Doormaster™
Professional is now
fitted.