Testing cat 1 | Page 37

Easy Integration for many system applications v1·v2c Monitors Device Existence on the Network Monitor networking equipment at a low cost The NH Tower initiates PING interaction with network devices to verify existence of up to 24 nodes. When the response to a PING fails, a warning with light and sound occurs to alert administrators. Many network devices (UPS, printers, routers, switches, etc.) generate SNMP TRAP messages when a failure occurs. The NHL tower can trigger a light and sound signal based on these SNMP TRAP messages to alert the administrator. NHL SNMP PING Device Monitor It can distinguish the various TRAPS. Register up to 16 groups (4 nodes per group). Among the 24 nodes, 12 nodes (13th - 24th) can be set up for more detailed monitoring parameters. Easy setup from a web browser Application Monitor Detailed tower setup is accessed from a web browser directly to its IP Address. Firmware can also be upgraded remotely. The tower can monitor important background applications and signal the administrator upon any failure. Web Setup Screen Communication Commands for many customized applications RSH SOCKET Transmission The RSH protocol is flexible with easily controllable commands. With the use of Network integrated management software; event information obtained from various monitoring tools etc., can be used as a trigger to cause a combination of flashing and alarm patterns to sound in synchronicity with the event. PHN Command Compatibility Controlled with 2 byte commands. * Compatible with NHE-3FB, NHC-3FB, NHM-3FB, and PHN-3FBE1. * Some functionality is limited. Event Occurence: Command Tier to light, alarm to sound PHN Example Code: 0x57,0x17 New PNS Command Compatibility The PNS command can be used to control all pattern information. * The PNS command is a unique command from PATLITE. Event Occurence: Command Tier to sound alarm Event Occurence: Command Tier to light, alarm to sound. PNS Example Code: 0x58,0x58,0x53,0x00,0x00,0x06,0x01,0x01,0x01,0x00,0x00,0x01 RSH Example Code: rsh 192.168.10.1 -l root alert 111001 Diagnostic / Reporting/ Notification Features Self-diagnosis E-mail Transmission il E-ma Send e-mail with a maximum of eight selectable events Up to eight events can be created and sent as a secure e-mail with the subject name and text corresponding to the event. SNMP v2c SNMP TRAP Transmission Can transmit from a maximum of eight network devices. The test switch on the front of the Body can check the Signal Tower and alarm operation functions easily without it being controlled through the network. 70 (5.5) 100 45 23.3 9.8 62 32 38 16 113 9.8 79 70.2 67 Options 35