Easy Integration for many system applications
v1·v2c
Monitors Device Existence on the Network
Monitor networking equipment at a low cost
The NH Tower initiates PING interaction with network devices
to verify existence of up to 24 nodes. When the response to a
PING fails, a warning with light and sound occurs to alert
administrators.
Many network devices (UPS, printers, routers, switches, etc.)
generate SNMP TRAP messages when a failure occurs. The NHL
tower can trigger a light and sound signal based on these
SNMP TRAP messages to alert the administrator.
NHL
SNMP
PING Device Monitor
It can distinguish the various TRAPS.
Register up to 16 groups (4 nodes
per group).
Among the 24 nodes, 12 nodes
(13th - 24th) can be set up for more
detailed monitoring parameters.
Easy setup from a
web browser
Application Monitor
Detailed tower setup is
accessed from a web
browser directly to its IP
Address. Firmware can also
be upgraded remotely.
The tower can monitor important background applications and
signal the administrator upon any failure.
Web Setup Screen
Communication Commands for many customized applications
RSH
SOCKET Transmission
The RSH protocol is flexible with easily
controllable commands.
With the use of Network integrated management
software; event information obtained from
various monitoring tools etc., can be used as a
trigger to cause a combination of flashing and
alarm patterns to sound in synchronicity with the
event.
PHN Command Compatibility
Controlled with 2 byte commands.
* Compatible with NHE-3FB, NHC-3FB, NHM-3FB, and PHN-3FBE1.
* Some functionality is limited.
Event Occurence:
Command Tier to light, alarm to sound
PHN Example Code: 0x57,0x17
New PNS Command Compatibility
The PNS command can be used to control all pattern
information.
* The PNS command is a unique command from PATLITE.
Event Occurence: Command Tier to sound alarm
Event Occurence: Command Tier to light, alarm to sound.
PNS Example Code:
0x58,0x58,0x53,0x00,0x00,0x06,0x01,0x01,0x01,0x00,0x00,0x01
RSH Example Code: rsh 192.168.10.1 -l root alert 111001
Diagnostic / Reporting/ Notification Features
Self-diagnosis
E-mail Transmission
il
E-ma
Send e-mail with a maximum
of eight selectable events
Up to eight events can be created and sent as a
secure e-mail with the subject name and text
corresponding to the event.
SNMP
v2c
SNMP TRAP Transmission
Can transmit from a maximum of eight network devices.
The test switch on the front of the
Body can check the Signal Tower
and alarm operation functions
easily without it being controlled
through the network.
70
(5.5)
100
45
23.3 9.8
62
32
38 16
113
9.8
79
70.2
67
Options
35