30RQ 182-522
Physical data, 30RQ 182-262 “B” + 30RQ 302-522 units
30RQ 182-262 “B” + 30RQ 302-522
Air conditioning application as per EN14511-3:2013
kW
Nominal cooling capacity
EER
kW/kW
Eurovent class, cooling
ESEER
kW/kW
Heating application as per EN14511-3:2013
kW
Nominal heating capacity
COP
kW/kW
Eurovent class, heating
kg
Operating weight - standard unit*
Compressors
Refrigerant*
Capacity control
Air heat exchangers
Fans
Quantity
Total air flow
l/s
Water heat exchanger
Dimensions
Length x depth x height
mm
NOTE: For the conditions please refer to page 73
*
182
202
232
262
302
342
372
402
432
462
522
177
2.93
B
3.97
198
2.70
C
3.68
217
2.84
C
4.18
250
2.62
D
3.67
279
2.63
D
4.03
309
2.46
E
3.75
333
2.63
D
3.50
368
2.49
E
3.54
392
2.59
D
3.61
435
2.59
D
3.43
470
2.40
E
3.25
184
205
221
268
2.85
2.83
2.98
2.85
C
C
C
C
1683
1785
1820
2020
Hermetic scroll, 48.3 r/s
R-410A
Pro-Dialog Plus
Grooved copper tubes and aluminium fins
Axial Flying Bird 4 fans with rotating shroud
4
4
4
4
303
2.73
D
2799
336
2.79
D
2986
367
2.84
C
3079
408
2.74
D
3233
446
2.79
D
3669
507
2.79
D
3909
554
2.72
D
4083
5
5
6
6
7
8
8
18056
18056
18056
Twin-circuit plate heat exchanger
22569
22569
27083
27083
31597
Direct-expansion twin-circuit. shell-and-tube heat exchanger
36111
36111
18056
2457 x 2253 x 2297
3604 x 2253 x 2297
4798 x 2253 x 2297
Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate.
Electrical data, 30RQ 182-262 “B” + 30RQ 302-522 units
30RQ (without hydronic module)
182
202
232
262
302
342
372
402
432
462
522
Power circuit
Nominal power supply
V-ph-Hz 400-3-50 ± 10%
24 V, via internal transformer
Control circuit supply
kW
Maximum power input* - circuits A + B/C
85
98
102
127
140
159
166
191
204
229
255
A
Nominal current draw** - circuits A + B/C
113
129
135
167
185
209
219
251
269
302
334
Maximum start-up current*** - circuits A + B/C A
353
375
348
426
448
481
492
536
558
601
645
*
Power input of the compressor(s) + fan(s) at maximum unit operating conditions saturated suction temperature 10°C, saturated condensing temperature 65°C at 400 V nominal voltage (values given on the
unit name plate).
** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C
*** Maximum instantaneous starting current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor).
Cooling mode
Heating mode
Ent W&