Test Drive carrier katalog | Page 95

30RQ 182-522 Physical data, 30RQ 182-262 “B” + 30RQ 302-522 units 30RQ 182-262 “B” + 30RQ 302-522 Air conditioning application as per EN14511-3:2013 kW Nominal cooling capacity EER kW/kW Eurovent class, cooling ESEER kW/kW Heating application as per EN14511-3:2013 kW Nominal heating capacity COP kW/kW Eurovent class, heating kg Operating weight - standard unit* Compressors Refrigerant* Capacity control Air heat exchangers Fans Quantity Total air flow l/s Water heat exchanger Dimensions Length x depth x height mm NOTE: For the conditions please refer to page 73 * 182 202 232 262 302 342 372 402 432 462 522 177 2.93 B 3.97 198 2.70 C 3.68 217 2.84 C 4.18 250 2.62 D 3.67 279 2.63 D 4.03 309 2.46 E 3.75 333 2.63 D 3.50 368 2.49 E 3.54 392 2.59 D 3.61 435 2.59 D 3.43 470 2.40 E 3.25 184 205 221 268 2.85 2.83 2.98 2.85 C C C C 1683 1785 1820 2020 Hermetic scroll, 48.3 r/s R-410A Pro-Dialog Plus Grooved copper tubes and aluminium fins Axial Flying Bird 4 fans with rotating shroud 4 4 4 4 303 2.73 D 2799 336 2.79 D 2986 367 2.84 C 3079 408 2.74 D 3233 446 2.79 D 3669 507 2.79 D 3909 554 2.72 D 4083 5 5 6 6 7 8 8 18056 18056 18056 Twin-circuit plate heat exchanger 22569 22569 27083 27083 31597 Direct-expansion twin-circuit. shell-and-tube heat exchanger 36111 36111 18056 2457 x 2253 x 2297 3604 x 2253 x 2297 4798 x 2253 x 2297 Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. Electrical data, 30RQ 182-262 “B” + 30RQ 302-522 units 30RQ (without hydronic module) 182 202 232 262 302 342 372 402 432 462 522 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V, via internal transformer Control circuit supply kW Maximum power input* - circuits A + B/C 85 98 102 127 140 159 166 191 204 229 255 A Nominal current draw** - circuits A + B/C 113 129 135 167 185 209 219 251 269 302 334 Maximum start-up current*** - circuits A + B/C A 353 375 348 426 448 481 492 536 558 601 645 * Power input of the compressor(s) + fan(s) at maximum unit operating conditions saturated suction temperature 10°C, saturated condensing temperature 65°C at 400 V nominal voltage (values given on the unit name plate). ** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C *** Maximum instantaneous starting current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Cooling mode Heating mode Ent W&