Test Drive carrier katalog | Page 63

30XW Physical data Standard-efficiency units 30XW-254 304 354 402 452 552 602 652 702 802 852 1002 1052 Air conditioning application as per EN14511-3: 2013 kW Nominal cooling capacity 273 307 359 459 473 532 538 677 730 792 839 1017 1060 EER kW/kW 5.32 5.30 5.24 5.21 5.35 5.21 5.17 5.39 5.30 5.19 5.39 5.26 5.20 Eurovent class A A A A A A A A A A A A A ESEER part-load performance kW/kW 5.67 5.58 5.58 5.75 5.77 5.78 5.66 6.06 6.02 5.79 5.94 6.3 6.34 kg Operating weight* 2017 2036 2072 2575 2575 2613 2644 3247 3266 3282 3492 5370 5408 Dimensions Depth mm 928 928 928 936 936 936 936 1040 1040 1040 1042 1036 1036 Length mm 2724 2724 2724 2741 2741 2741 2741 3059 3059 3059 2780 4025 4025 Height mm 1567 1567 1567 1692 1692 1692 1692 1848 1848 1848 1898 1870 1870 High-efficiency units 30XW-P 512 562 712 812 862 1012 1162 Air conditioning application as per EN14511-3: 2013 kW 509 577 737 786 861 1039 1157 Nominal cooling capacity kW/kW 5.71 EER 5.64 5.83 5.62 5.65 5.73 5.78 Eurovent class A A A A A A A kW/kW 6.09 ESEER 6.14 6.41 6.24 6.17 6.74 6.83 kg Operating weight* 2981 3020 3912 3947 3965 6872 6950 Dimensions Depth mm 936 936 1069 1069 1069 1039 1039 Length mm 3059 3059 3290 3290 3290 4730 4730 Height mm 1743 1743 1950 1950 1950 1997 1997 Physical data for all units Semi-hermetic 06T screw compressors, 50 r/s Compressors R-134a Refrigerant Pro-Dialog, electronic expansion valves (EXV) Capacity control Flooded multi-pipe type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections Evaporator Flooded multi-pipe type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections Condenser 1154 1252 1352 1452 1552† 1652† 1702† 1141 5.30 A 6.23 5698 1257 5.69 A 6.73 7066 1342 5.51 A 6.44 7267 1453 5.36 A 6.27 7305 1547 5.29 NA 6.06 7337 1036 1156 4025 4730 1925 2051 1314 1156 4730 2051 1464 1156 4730 2051 1156 4730 2051 1612† 1657 5.67 NA 6.62 8681 1732 5.68 NA 6.56 8699 1902 1902 4790 4790 1515 1515 1762† 1323 5.80 A 6.65 7542 1452 5.58 A 6.36 7752 1626 5.87 NA 6.80 10910 1756 5.79 NA 6.59 10946 1162 4730 2051 1162 4730 2051 2129 4832 1562 2129 4832 1562 NOTE: For the conditions please refer to page 31. † These models are not Eurovent certified, as they are out of Eurovent certification program scope. * Weights are guidelines only. The refrigerant charge is given on the unit nameplate. Electrical data Standard-efficiency units 30XW-Nominal power supply, all units Control circuit, all units Maximum start-up current* Circuit A Circuit B Maximum power input** Circuit A Circuit B Maximum current drawn (Un)** Circuit A Circuit B High-efficiency units 30XW-P Maximum start-up current* Circuit A/B Maximum power input** Circuit A/B Maximum current drawn (Un)** Circuit A/B * ** 254 304 354 402 452 V-ph-Hz 400-3-50 ± 10% 24 V via the built-in transformer 552 602 652 702 802 852 1002 1052 1154 1252 1352 1452 1552 1652 1702 A A 233 - 233 - 303 - 414 - 414 - 414 - 414 - 587 - 587 - 587 - 587 - 414 414 414 414 414 414 587 414 587 587 587 587 587 587 587 587 587 587 kW kW 76 - 89 - 97 - 128 - 135 - 151 - 151 - 184 - 200 - 223 - 223 - 150 135 151 151 151 151 184 151 184 184 200 200 223 223 223 202 223 223 A A 123 512 145 - 160 562 206 - 217 712 242 - 242 - 242 217 1162 242 242 242 242 1314 295 242 812 295 317 862 295 295 1464 317 351 317 351 1612 351 351 317 351 1762 A 414/- 414/- 587/- 587/- 587/- 414/414 414/414 587/414 587/587 587/587 587/587 kW 135/- 151/- 184/- 200/- 223/- 134/134 151/151 184/151 184/184 200/200 223/223 A 217/- 242/- 295/- 317/- 351/- 217/217 242/242 295/242 295/295 317/317 351/351 Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at operation with maximum unit power input. Values obtained at operation with maximum unit power input. Values given on the unit name plate. From approx. 45% to full load Part load limit approx. 35% Minimum load limit approx. 15% 55 50 45 40 35 30 25 20 15 0 5 10 15 20 Evaporator leaving water temp., °C Operating range, option 150 Condenser leaving water temperature, °C Operating range, standard units Condenser leaving water temp., °C 351 351 1012 70 From approx. 60% to full load Part load limit approx. 50% Minimum load limit approx. 30% 65 60 55 50 45 40 35 30 25 20 0 5 10 15 20 Evaporator leaving water temperature, °C 61