Test Drive carrier katalog | Page 63
30XW
Physical data
Standard-efficiency units 30XW-254
304
354
402
452
552
602
652
702
802
852
1002 1052
Air conditioning application as per EN14511-3: 2013
kW
Nominal cooling capacity
273
307
359
459
473
532
538
677
730
792
839
1017 1060
EER
kW/kW 5.32
5.30
5.24
5.21
5.35
5.21
5.17
5.39
5.30
5.19
5.39
5.26
5.20
Eurovent class
A
A
A
A
A
A
A
A
A
A
A
A
A
ESEER part-load performance kW/kW 5.67
5.58
5.58
5.75
5.77
5.78
5.66
6.06
6.02
5.79
5.94
6.3
6.34
kg
Operating weight*
2017 2036 2072 2575 2575 2613 2644 3247 3266 3282 3492 5370 5408
Dimensions
Depth
mm
928
928
928
936
936
936
936
1040 1040 1040 1042 1036 1036
Length
mm
2724 2724 2724 2741 2741 2741 2741 3059 3059 3059 2780 4025 4025
Height
mm
1567 1567 1567 1692 1692 1692 1692 1848 1848 1848 1898 1870 1870
High-efficiency units 30XW-P
512
562
712
812
862
1012
1162
Air conditioning application as per EN14511-3: 2013
kW
509
577
737
786
861
1039
1157
Nominal cooling capacity
kW/kW 5.71
EER
5.64
5.83
5.62
5.65
5.73
5.78
Eurovent class
A
A
A
A
A
A
A
kW/kW 6.09
ESEER
6.14
6.41
6.24
6.17
6.74
6.83
kg
Operating weight*
2981
3020
3912
3947
3965
6872
6950
Dimensions
Depth
mm
936
936
1069
1069
1069
1039
1039
Length
mm
3059
3059
3290
3290
3290
4730
4730
Height
mm
1743
1743
1950
1950
1950
1997
1997
Physical data for all units
Semi-hermetic 06T screw compressors, 50 r/s
Compressors
R-134a
Refrigerant
Pro-Dialog, electronic expansion valves (EXV)
Capacity control
Flooded multi-pipe type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections
Evaporator
Flooded multi-pipe type, maximum operating pressure 1000 kPa, 3/8” NPT drain and vent connections
Condenser
1154
1252
1352
1452
1552† 1652† 1702†
1141
5.30
A
6.23
5698
1257
5.69
A
6.73
7066
1342
5.51
A
6.44
7267
1453
5.36
A
6.27
7305
1547
5.29
NA
6.06
7337
1036 1156
4025 4730
1925 2051
1314
1156
4730
2051
1464
1156
4730
2051
1156
4730
2051
1612†
1657
5.67
NA
6.62
8681
1732
5.68
NA
6.56
8699
1902 1902
4790 4790
1515 1515
1762†
1323
5.80
A
6.65
7542
1452
5.58
A
6.36
7752
1626
5.87
NA
6.80
10910
1756
5.79
NA
6.59
10946
1162
4730
2051
1162
4730
2051
2129
4832
1562
2129
4832
1562
NOTE: For the conditions please refer to page 31.
† These models are not Eurovent certified, as they are out of Eurovent certification program scope.
*
Weights are guidelines only. The refrigerant charge is given on the unit nameplate.
Electrical data
Standard-efficiency units 30XW-Nominal power supply, all units
Control circuit, all units
Maximum start-up current*
Circuit A
Circuit B
Maximum power input**
Circuit A
Circuit B
Maximum current drawn (Un)**
Circuit A
Circuit B
High-efficiency units 30XW-P
Maximum start-up current*
Circuit A/B
Maximum power input**
Circuit A/B
Maximum current drawn (Un)**
Circuit A/B
*
**
254
304
354
402
452
V-ph-Hz 400-3-50 ± 10%
24 V via the built-in transformer
552
602
652
702
802
852
1002
1052
1154
1252
1352
1452
1552
1652
1702
A
A
233
-
233
-
303
-
414
-
414
-
414
-
414
-
587
-
587
-
587
-
587
-
414
414
414
414
414
414
587
414
587
587
587
587
587
587
587
587
587
587
kW
kW
76
-
89
-
97
-
128
-
135
-
151
-
151
-
184
-
200
-
223
-
223
-
150
135
151
151
151
151
184
151
184
184
200
200
223
223
223
202
223
223
A
A
123
512
145
-
160
562
206
-
217
712
242
-
242
-
242
217
1162
242
242
242
242
1314
295
242
812
295
317
862
295
295
1464
317
351
317
351
1612
351
351
317
351
1762
A
414/-
414/-
587/-
587/-
587/-
414/414
414/414
587/414
587/587
587/587
587/587
kW
135/-
151/-
184/-
200/-
223/-
134/134
151/151
184/151
184/184
200/200
223/223
A
217/-
242/-
295/-
317/-
351/-
217/217
242/242
295/242
295/295
317/317
351/351
Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at operation with
maximum unit power input.
Values obtained at operation with maximum unit power input. Values given on the unit name plate.
From approx. 45% to full load
Part load limit approx. 35%
Minimum load limit approx. 15%
55
50
45
40
35
30
25
20
15
0
5
10
15
20
Evaporator leaving water temp., °C
Operating range, option 150
Condenser leaving water temperature, °C
Operating range, standard units
Condenser leaving water temp., °C
351
351
1012
70
From approx. 60% to full load
Part load limit approx. 50%
Minimum load limit approx. 30%
65
60
55
50
45
40
35
30
25
20
0
5
10
15
20
Evaporator leaving water temperature, °C
61