30XA Physical data 30XA 252 302 Air conditioning application as per EN14511-3: 2013 kW 267 291 Nominal cooling capacity, unit with option 279* Unit with options 279 and 119** kW 273 298 EER, unit with option 279 kW/kW 3.00 2.96 EER, unit with options 279 and 119 kW/kW 3.13 3.10 Eurovent class, unit with option 279 B B Eurovent class, unit with options 279 & 119 A A ESEER, unit with option 279 kW/kW 3.94 4.20 ESEER, unit with options 279 and 119 kW/kW 3.89 3.96 Operating weight*** 3410 3450 Unit with options 279 and 119 kg Dimensions Length, standard unit mm mm Depth + height Refrigerant Compressors Control Condensers Fans Quantity, standard unit - option 119* Evaporator NOTE: For the conditions, please refer to page 31. 352 402 452 502 602 702 752 802 852 902 1002 1102 1112 1202 1212 1302 1312 1352 1382 1402 1502 1702† 318 378 426 473 601 654 691 759 807 875 960 1119 1107 1216 1218 1294 1285 1383 1377 1436 1443 1611 325 2.98 3.09 B B 4.20 4.01 391 3.08 3.21 B A 4.10 3.88 442 2.89 3.08 C B 4.13 3.93 499 2.93 3.15 B A 4.09 3.93 612 3.03 3.13 B A 4.08 3.84 679 3.11 3.31 A A 4.10 4.07 723 2.91 3.08 B B 4.00 3.87 785 2.88 3.10 C A 4.06 3.92 841 2.98 3.24 B A 4.09 4.03 886 2.91 3.12 B A 3.81 3.82 976 2.95 3.09 B B 3.82 3.74 1147 3.02 3.24 B A 4.05 4.08 1144 3.04 3.27 B A 3.89 4.00 1235 2.96 3.09 B B 3.93 3.93 1247 3.09 3.23 B A 4.08 4.10 3490 4313 4883 4814 5707 5857 6157 6457 6958 7258 7836 9590 9410 10020 9570 1317 2.87 3.09 C B 3.88 4.00 1326 2.91 3.16 B A 3.61 3.89 1437 2.64 3.09 D B 3.69 4.03 1433 2.77 3.06 C B 3.54 3.91 1480 2.97 3.20 B A 3.95 3.98 1525 2.87 3.19 C NA 3.85 3.97 1682 3.00 3.22 NA NA 3.81 3.87 10410 10180 10770 10270 3953 3953 6958 7776 7926 6958 3604 3604 3604 4798 4798 5992 7186 7186 7186 7186 8380 8380 9574 11962 11962 11962 11962 11962 11962 11962 11962 9574 9574 8380 4798 4798 8380 2253 x 2297 R-134a 06T semi-hermetic screw compressors, 50 r/s Pro-Dialog, electronic expansion valve (EXV) Aluminium micro-channel heat exchangers Axial Flying Bird 4 fans with rotating shroud 6 6 6 8 8 9 11 12 12 12 14 14 16 19 19 20 20 20 20 20 20 24 24 28 Flooded shell-and-tube type † These models are not Eurovent certified, as they are out of Eurovent certification program scope. * Option 279 = compressor enclosure ** Option 119 = high energy efficiency *** Weights are guidelines only. The values for sizes 1402, 1502 and 1702 are for modules 1 and 2. Note: Unit sizes 30XA 1402 to 1702 are supplied in two field-assembled modules. Electrical data 30XA 252 302 352 402 452 502 602 702 752 802 852 902 1002 1102 1112 1202 1212 1302 1312 1352 1382 1402 1502 1702 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% 24 V via internal transformer Control circuit Max. start-up current, circuits A + B/C + D* Unit with option 279 A 269 269 287 402 505 505 574 606 773 803 805 893 941 574/587 587/772 773/587 587/772 803/587 772/772 891/587 772/772 893/587 941/587 805/805 Unit with option 279 A 274 274 292 407 510 510 583 616 782 812 815 905 954 583/587 587/772 782/587 587/772 812/587 772/772 901/587 772/772 905/587 954/587 815/815 and 119 Max. power input, circuits A + B/C + D** Unit with option 279 kW 121 131 141 165 185 204 247 267 293 312 343 359 420 247/210 182/279 293/210 211/302 342/210 258/278 388/209 278/299 390/210 420/210 343/343 Unit with option 279 kW 126 136 147 172 192 212 257 278 304 323 356 372 435 257/217 186/286 304/217 216/309 353/217 262/284 400/216 284/305 405/217 435/217 356/356 and 119 Max. unit current draw, circuits A + B/C + D** Unit with option 279 A 198 215 233 270 303 335 404 436 492 522 572 611 707 404/354 313459 492/354 359/496 568/354 426/456 655/352 456/491 661/354 707/354 572/572 Unit with option 279 A 208 226 243 284 316 350 423 457 512 542 596 635 734 423/367 321/470 512/367 367/508 588/367 436/466 678/364 466/501 688/367 734/367 596/596 and 119 * Instantaneous start-up current (operating current of the smallest compressor + fan current + locked rotor current in star connection of the largest compressor). Values obtained at operation with maximum unit power input. ** Values obtained at operation with maximum unit power input. Values given on the unit name plate. Circuit D for size 1702 only. Note: Unit sizes 30XA 1102 to 1702 have two power connection points (circuits A + B and circuits C + D). Operating range 30XA 30XA unit with option 119 Operating range, unit equipped with option 28 (winter operation) Air entering temperature, °C Air entering temperature, °C Legend Evaporator leaving water temperature, °C Below 0°C air temperature the unit must either be equipped with the evaporator frost protection option (41A or 41B), or the water loop must be protected against frost by using a frost protection solution (by the installer). Part load average Evaporator leaving water temperature, °C 51