Test Drive carrier katalog | Page 154

DIRECT-FIRED DOUBLE-EFFECT ABSORPTION CHILLERS/HEATERS Industrial SUPER ABSORPTION Display and control board Features 8 1 2 STOP RUN CHILLER / HEATER 5 #1ABS PUMP #2ABS PUMP 9 10 11 12 REF PUMP PURGE PUMP SET BACK BURNER STAND BY HEATING 6 COOLING DILUTION REMOTE SAFETY CIRCUIT BUZZER STOP COMBUSTION CHILLER/HEATER A ARM L BURNER ALARM POWER STOP LOCAL OPERATION RUN 4 7 3 symbol 1 1 2 2 3 4 3 5 4 6 5 7 8 6 9 7 10 8 11 12 9 GL 10 43P 11 12 43ES Name 16DJ Lamp color Operation Red Operation indication lamp indication Stop indication lamp Green Stop indication lamp Alarm indication Orange Combustion indication lamp Red Alarm indication Cooling / Heating indication lamp Orange Combustion indication Remote / Local select button with lamp Red Cooling/heating indication lamp Red Operation select button with Data display Remote/local select button 7segment LED(Red Stand by indication lamp Red Operation mode selection Dilution indication lamp Orange Data display indication lamp Safety circuit Red Power indication lamp White Stand-by indication Purgerindication lamp Green Dilution indication Purge pump on - of f switch Safety circuit indication Emergency stop switch Power indication • Twenty-three sizes with nominal cooling capacities from 352 to 5274 kW and heating capacities from 268 to 4026 kW. • The 16DJ absorption chillers/heaters offer building owners a better solution for many new and retrofit applications. Installation of a direct-fired chiller/heater eliminates the need for a boiler, reducing the initial cost of the system. • Excellent for peak shaving during high electrical demand periods. • Allows diversification of critical cooling requirements. Critical loads are met with minimal electrical power input. • Allows use of smaller emergency generators since the electrical load associated with an absorption chiller is minimal. • Ozone-friendly and CFC-free. • Minimises global warming effect by greatly reducing power consumption. • Reduced noise and vibration levels. The absorption chiller does not use a large motor-compressor, leading to quiet, vibration-free operation. • Small footprint. The high efficiency associated with double-effect chillers results in reducing the required installation space. • Auto-diagnosis system monitors operating conditions, predicts chiller information and maintains stable operation. • Advanced high-precision control system. • Absorption pump with inverter control for efficient, energy-saving operation. • High-performance purge system minimises maintenance requirements. • State-of-the-art protection devices guarantee enhanced operating safety. 152