Test Drive carrier katalog | Page 152

DOUBLE-EFFECT STEAM-FIRED ABSORPTION CHILLERS Industrial SUPER ABSORPTION Display and control board Features 8 1 2 STOP RUN CHILLER / HEATER 5 #1ABS PUMP #2ABS PUMP 9 10 11 12 REF PUMP PURGE PUMP SET BACK BURNER STAND BY HEATING 6 COOLING DILUTION REMOTE SAFETY CIRCUIT BUZZER STOP COMBUSTION CHILLER/HEATER A ARM L BURNER ALARM POWER STOP LOCAL OPERATION RUN 4 7 3 symbol 1 1 2 2 3 3 4 5 4 6 5 7 6 8 9 7 10 8 11 9 12 GL 10 43P 11 12 43ES Name 16NK Lamp color Operation indication lamp Operation indication Red Stop indication Green Stop indication lamp Alarm indication lamp Orange Alarm indication Combustion indication lamp Red Cooling / Heating indication lamp Orange Combustion indication Remote / Local select button Red Cooling/heating indication with lamp Operation select button with lamp Red Remote/local select button 7segment LED(Red Data display Stand by indication lamp Red Operation mode selection Dilution indication lamp Orange Data display Safety circuit indication lamp Red Stand-by indication Power indication lamp White Purgerindication lamp Green Dilution indication Purge on of switch Safety pumpstop-fswitch circuit indication Emergency Power indication • Eighteen sizes with nominal cooling capacities from 345 to 4652 kW. • The 16NK absorption chillers are designed for cooling applications where low-pressure steam is available as waste heat. • Can tie into district steam systems. • Allows diversification of critical cooling requirements. Critical cooling loads are met with minimal electrical power input. • Allows use of smaller emergency generators since the electrical load associated with an absorption chiller is minimal. • Ozone-friendly and CFC-free. • Minimises global warming effect by greatly reducing power consumption and eliminating the generation of greenhouse gases. • Reduced noise and vibration levels. The absorption chiller does not use a large motor-compressor, leading to quiet, vibration-free operation. • Small footprint. The high efficiency associated with double-effect chillers results in a reduction of the required installation space. • Auto-diagnosis system monitors operating conditions, predicts chiller information and maintains stable operation. • Advanced high-precision control system. • Absorption pump with inverter control for efficient, energy-saving operation. • High-performance purge system minimises maintenance requirements. • State-of-the-art protection devices guarantee enhanced operating safety. 150