Test Drive carrier katalog | Page 149

16LJ Physical data 16LJ Cooling capacity Chilled water system* Flow rate Pressure drop Connection (ANSI) Retention volume Cooling water system** Flow rate Pressure drop Connection (ANSI) Retention volume Hot water system*** Flow rate Pressure drop Connection (ANSI) Retention volume Dimensions Length A Height B Width C Operating weight Power supply Total current drawn kW 02 140 03 176 11 264 12 316 13 387 14 475 21 545 22 633 23 738 24 844 l/s kPa in m3 3.50 71 2 - 5.61 60 2-1/2 - 7.00 59 2-1/2 - 11.40 56 3 0.11 13.60 61 3 0.13 16.70 36 4 0.15 20.40 40 4 0.17 23.50 35 5 0.22 27.30 38 5 0.25 31.80 74 5 0.28 36.30 77 5 0.30 l/s kPa in m3 10.10 77 3 - 16.20 48 4 - 20.20 49 4 - 17.00 38 5 0.33 20.40 39 5 0.37 25.00 67 5 0.40 30.70 72 5 0.45 35.20 68 6 0.58 40.90 71 6 0.63 47.70 42 8 0.69 54.40 45 8 0.76 l/s kPa in m3 mm 3.06 52 2 - 4.89 31 2-1/2 - 6.11 36 2-1/2 - 10.40 31 4 0.11 12.50 12 4 0.12 15.20 29 4 0.14 18.70 32 4 0.16 21.50 31 5 0.20 24.90 37 5 0.22 29.00 30 6 0.25 33.00 31 6 0.28 kg V-ph-Hz A 1745 2115 1255 2070 2450 2115 1255 2680 2450 2115 1435 3150 2740 2200 1400 4400 3750 2200 1400 5400 3750 2200 1400 5600 3850 2350 1560 6800 3850 2350 1560 7300 4870 2370 1560 8300 4870 2370 1560 8900 4.8 4.8 4.8 2740 2200 1400 4200 400-3-50 6.1 6.1 6.1 6.1 8.8 8.8 8.9 8.9 kW 31 949 32 1055 41 1178 42 1319 51 1477 52 1653 53 1846 63 2637 72 3165 82 3956 l/s kPa in m3 40.80 75 6 0.35 45.60 78 6 0.38 50.80 74 8 0.49 56.70 64 8 0.56 63.60 54 8 0.70 71.10 73 8 0.77 79.40 96 8 0.83 114 46 10 1.21 136 105 12 1.53 170 46 14 1.94 l/s kPa in m3 61.40 36 8 0.98 68.10 37 8 1.05 76.10 38 10 1.31 85.30 40 10 1.41 95.30 92 12 1.97 107 86 12 2.13 119 45 12 2.27 170 58 14 3.24 205 44 16 4.10 256 68 16 5.11 l/s kPa in m3 mm 16LJ Cooling capacity Chilled water system* Flow rate Pressure drop Connection (ANSI) Retention volume Cooling water system** Flow rate Pressure drop Connection (ANSI) Retention volume Hot water system*** Flow rate Pressure drop Connection (ANSI) Retention volume Dimensions Length A Height B Width C Operating weight Power supply Total current drawn 01 88 37.00 30 6 0.33 42.00 30 6 0.36 46.00 30 8 0.44 52.00 30 8 0.48 58.00 28 8 0.56 65.00 38 8 0.61 73.00 50 8 0.66 94.40 19 10 1.08 113 19 10 1.27 142 25 10 1.55 4920 2610 1630 10700 4920 2610 1630 11300 5070 2860 1700 13100 5210 3210 1990 18500 5750 3210 1990 20000 6250 3210 1990 21400 6750 3660 2420 31100 6990 3780 2650 39100 7590 3990 2820 46600 10.90 10.90 10.90 5070 2860 1700 13600 400-3-50 10.90 10.90 10.90 10.90 30.20 37.50 39.60 kg V-ph-Hz A * Sizes 01/02/03: 12.0/6.0°C; all other sizes 12.2/6.7°C (Fooling factor = 0.018 m2 K/kW) ** Sizes 01/02/03: 29.0/34.0°C; all other sizes 29.4/38.4°C (Fooling factor = 0.044 m2 K/kW) *** Sizes 01/02/03: 90.0/80.0°C; all other sizes 95.0/86.0°C (Fooling factort = 0.018 m2 K/kW) C A B 147