Test Brochure - Natural Winners | Page 4

4 Eppendorf Liquid Handling Instruments Selection Guide Air-cushion principle Model Eppendorf Research ® plus Pipetting of aqueous liquids Eppendorf Reference ® 2 Pipetting of aqueous liquids Eppendorf Xplorer ®  / Xplorer ® plus Pipetting of aqueous liquids Eppendorf Easypet ® 3 Pipetting of aqueous liquids with serological and volumetric pipettes Eppendorf Pipet Helper ® Pipetting of aqueous liquids with serological and volumetric pipettes Product type Pipette Pipette Pipette Pipette controller Pipette controller Operation Mechanical, separate control button and ejector Air-cushion Mechanical, combined control button and ejector Air-cushion Electronic, separate control button and ejector Air-cushion Electronic Manual Air-cushion Air-cushion Positioning Ultra light weight and pipetting force for ultimate ergonomics Reliability in robust- ness and results Intuitive and fast pipetting Overall ergonomic concept with new speed control for stress-free pipetting Volume range 0.1 µL–10 mL 0.1 µL–10 mL 0.5 μL–10 mL 0.1–100 mL A perfect instrument for inexperienced users because of its robust and intuitive design 0.1–100 mL Available options 1-channel 8-channel 12-channel 1-channel 8-channel 12-channel 1-channel 8-channel 12-channel 1-channel 1-channel RFID tracking Yes (read option) Yes (read & write option) Yes (read & write option) Yes (read option) No Autoclavable Yes Yes Yes (lower part) Yes Consumables epT.I.P.S. ® and other pipette tips epT.I.P.S. ® and other pipette tips epT.I.P.S. ® and other pipette tips Purity grades of consumables > > Eppendorf Quality™ > > PCR clean & sterile > > Eppendorf Biopur ® > > Forensic DNA Grade > > Eppendorf Quality™ > > PCR clean & sterile > > Eppendorf Biopur ® > > Forensic DNA Grade > > Eppendorf Quality™ > > PCR clean & sterile > > Eppendorf Biopur ® > > Forensic DNA Grade Page 8 10 12 Yes (pipette adapter and aspirating cone) Eppendorf Serological Pipets and other volumetric and serological pipettes > > Sterile > > Free of detectable RNase & DNase > > Free of detectable pyrogens > > Free of detectable DNA > > Forensic DNA Grade 14 Application Pipetting type Air-cushion principle Standard pipettes work with an air cushion that separates the piston from the liquid. The air is displaced by the piston. The volume of the displaced air is equivalent to the volume of liquid aspirated. Eppendorf Serological Pipets and other volumetric and serological pipettes > > Sterile > > Free of detectable RNase & DNase > > Free of detectable pyrogens > > Free of detectable DNA > > Forensic DNA Grade 14