Servomex Gas Guide 2022 | Page 50

IP & E APPLICATION

ETHYLENE OXIDE PRODUCTION

The production of ethylene oxide ( EO ), a versatile chemical building block , relies on precise gas analysis measurements to ensure process safety and high productivity .
EO is formed in a reaction between oxygen and ethylene , and requires highly accurate monitoring of oxygen levels to protect the process against a risk of explosion . Quality and process control measurements are also made to support efficiency .
Safety is an essential concern , especially around the process reactors where hazardous flammable samples containing ethylene , oxygen , ethylene oxide and methane may be present .

KEY SOLUTIONS

SERVOTOUGH OxyExact 2200
To provide safety-critical oxygen analysis , Servomex supplies a dual or triple-redundancy gas analysis system using SERVOTOUGH OxyExact 2200 analyzers . Specifically designed for hazardous area operation , these Paramagnetic analyzers deliver the accurate , reliable measurements needed as part of a Safety Integrated System ( SIS ).
P50