Service Solahart Serpong (081313462267) Distributor Resmi | Page 2

MDV Series - Electric Boosted Open Circuit Split Systems These systems have limited frost protection and are not suitable for harsh water regions^. MLV and MTV Systems Model 272MLV 273MLV 322MLV 323MLV 412MLV 413MLV 414MLV 272MTV 322MTV 412MTV 413MTV Tank Model 270MDV 270MDV 320MDV 320MDV 410MDV 410MDV 410MDV 270MDV 320MDV 410MDV 410MDV Collector L L L L L L L TBT200 TBT200 TBT200 TBT200 No. of collectors 2 3 2 3 2 3 4 2 2 2 3 Solar Storage Tank Collectors General Tank Model Storage capacity Boost capacity (electric) 270MDV 320MDV 410MDV litres 270 320 410 US gal 71.3 84.5 108.3 litres 140 170 220 US gal 37 44.9 58.1 Installation Indoor / Outdoor Solar controller kit PN 299280 Weight  empty Weight  full Height Width Depth Aperture (heating) area m2 1.87 ft2 20 Dimensions length mm 1937 in 76.3 width mm 1022 in 40.3 height mm 77 in 3.0 Capacity litres 3 US gal 0.8 Working pressure kPa 1000 psi 145 empty kg 33 lbs 73 full kg 35 lbs 77 L Collector 1 1 1 kg 78 88 109 lbs 172 194 241 kg 348 414 525 Absorber material aluminium lbs 767 912 1158 Riser material copper tube m 1.395 1.640 1.840 Tray material in 54.9 64.6 72.5 Insulation material - base m 0.640 0.640 0.690 Glass Weight Absorber surface in 25.2 25.2 27.2 TBT200 Collector m 0.680 0.680 0.730 Weight 28.7 in 26.8 26.8 Black polyester powder coat 0.7mm aluminium 38mm polyester blanket 3.2mm tempered low iron glass empty kg 37 lbs 82 full kg 39 lbs 86 Absorber surface Tinox sputtered selective Absorber material Electric Boost Specifications Riser material Heating unit type Tray material Copper sheath immersion element Supply voltage 240V 50Hz 30°C 40°C 50°C kW Amps litres/hour litres/hour litres/hour 2.4 10 68 52 41 Collector Installation 3.6 15 103 77 62 Roof area dimensions 103 83 Length* Width* Water Supply 3.2mm tempered low iron glass Zincalume is a registered trademark of Bluescope Steel Limited Current 137 38 mm glass wool blanket Glass ® Rating 20 0.55 mm Zincalume® Insulation material - base Recovery rate @ 240 V and temperature rise of: 4.8 copper copper tube 2 3 4 m 2.0 2.0 2.0 78.8 in 78.8 78.8 m 2.3 3.4 4.5 in 90.6 133.9 177.2 TPR valve setting kPa 1000 psi 145 Solar kits - L collector ECV * kPa 850 psi 125 Collector kit PN 12104297 1 1 1 Max. supply pressure with ECV without ECV Collector add on kit PN 12104405 0 1 2 kPa 680 psi 100 Solar kits - TBT200 collector kPa 800 psi 115 Collector kit PN 12104794 1 1 N/A Min. supply pressure kPa 200 psi 29 Collector add on kit PN 12104795 0 1 N/A setting Water Connections cold RP¾/20 hot RP¾/20 solar DN15 compression fittings (solar hot and solar cold inlets to tank RP¾/20) *Expansion Control Valve (ECV) is not supplied. *An additional 0.9m (35.4in) should be left on all four sides of the installation for safe access and servicing. The Streamline MLV and MTV systems can be installed as a solar preheater with an inline Solahart gas booster water heater. Refer to the Solahart gas booster specification sheet for further details on the gas booster. ^ Limited frost protection – these systems have a level of freeze protection designed to guard against freeze conditions. These systems have a Solahart warranty for freeze damage (Australia only – conditions apply) when the water heater is installed at an altitude not exceeding 400 m above sea level. Harsh water regions – the Solahart warranty may not apply if the water heater is connected to a water supply which: is scaling with a Saturation Index > +0.8, or: is corrosive with a Saturation Index <-1.0, or; has a Total Dissolved Solids content >2500 mg/L. Technical data is subject to change. Solahart Australia Tel: 1300 769 475 www.solahart.com.au Solahart International Tel: +61 8 9351 4600 www.solahart.com Reorder: SHB/MDV SH997SEOC 2013 March