Service Solahart Serpong (081313462267) Distributor Resmi | Seite 2
MDV Series - Electric Boosted Open Circuit Split Systems
These systems have limited frost protection and are not suitable for harsh water regions^.
MLV and MTV Systems
Model
272MLV
273MLV
322MLV
323MLV
412MLV
413MLV
414MLV
272MTV
322MTV
412MTV
413MTV
Tank Model
270MDV
270MDV
320MDV
320MDV
410MDV
410MDV
410MDV
270MDV
320MDV
410MDV
410MDV
Collector
L
L
L
L
L
L
L
TBT200
TBT200
TBT200
TBT200
No. of collectors
2
3
2
3
2
3
4
2
2
2
3
Solar Storage Tank
Collectors General
Tank Model
Storage capacity
Boost capacity (electric)
270MDV
320MDV
410MDV
litres
270
320
410
US gal
71.3
84.5
108.3
litres
140
170
220
US gal
37
44.9
58.1
Installation
Indoor / Outdoor
Solar controller kit PN 299280
Weight empty
Weight full
Height
Width
Depth
Aperture (heating) area
m2
1.87
ft2
20
Dimensions
length
mm
1937
in
76.3
width
mm
1022
in
40.3
height
mm
77
in
3.0
Capacity
litres
3
US gal
0.8
Working pressure
kPa
1000
psi
145
empty
kg
33
lbs
73
full
kg
35
lbs
77
L Collector
1
1
1
kg
78
88
109
lbs
172
194
241
kg
348
414
525
Absorber material
aluminium
lbs
767
912
1158
Riser material
copper tube
m
1.395
1.640
1.840
Tray material
in
54.9
64.6
72.5
Insulation material - base
m
0.640
0.640
0.690
Glass
Weight
Absorber surface
in
25.2
25.2
27.2
TBT200 Collector
m
0.680
0.680
0.730
Weight
28.7
in
26.8
26.8
Black polyester powder coat
0.7mm aluminium
38mm polyester blanket
3.2mm tempered low iron glass
empty
kg
37
lbs
82
full
kg
39
lbs
86
Absorber surface
Tinox sputtered selective
Absorber material
Electric Boost Specifications
Riser material
Heating unit type
Tray material
Copper sheath immersion element
Supply voltage
240V 50Hz
30°C
40°C
50°C
kW
Amps
litres/hour
litres/hour
litres/hour
2.4
10
68
52
41
Collector Installation
3.6
15
103
77
62
Roof area dimensions
103
83
Length*
Width*
Water Supply
3.2mm tempered low iron glass
Zincalume is a registered trademark of Bluescope Steel Limited
Current
137
38 mm glass wool blanket
Glass
®
Rating
20
0.55 mm Zincalume®
Insulation material - base
Recovery rate @ 240 V and temperature rise of:
4.8
copper
copper tube
2
3
4
m
2.0
2.0
2.0
78.8
in
78.8
78.8
m
2.3
3.4
4.5
in
90.6
133.9
177.2
TPR valve setting
kPa
1000
psi
145
Solar kits - L collector
ECV *
kPa
850
psi
125
Collector kit PN 12104297
1
1
1
Max. supply pressure
with ECV
without ECV
Collector add on kit PN 12104405
0
1
2
kPa
680
psi
100
Solar kits - TBT200 collector
kPa
800
psi
115
Collector kit PN 12104794
1
1
N/A
Min. supply pressure
kPa
200
psi
29
Collector add on kit PN 12104795
0
1
N/A
setting
Water Connections
cold
RP¾/20
hot
RP¾/20
solar
DN15 compression fittings
(solar hot and solar cold inlets to tank
RP¾/20)
*Expansion Control Valve (ECV) is not supplied.
*An additional 0.9m (35.4in) should be left on all four sides of the installation for safe
access and servicing.
The Streamline MLV and MTV systems can be installed as a solar preheater with an
inline Solahart gas booster water heater. Refer to the Solahart gas booster specification
sheet for further details on the gas booster.
^ Limited frost protection – these systems have a level of freeze protection designed to guard against freeze conditions. These systems have a Solahart warranty for freeze damage
(Australia only – conditions apply) when the water heater is installed at an altitude not exceeding 400 m above sea level.
Harsh water regions – the Solahart warranty may not apply if the water heater is connected to a water supply which: is scaling with a Saturation Index > +0.8, or: is corrosive with a
Saturation Index <-1.0, or; has a Total Dissolved Solids content >2500 mg/L.
Technical data is subject to change.
Solahart Australia Tel: 1300 769 475 www.solahart.com.au
Solahart International Tel: +61 8 9351 4600 www.solahart.com
Reorder: SHB/MDV SH997SEOC 2013 March