Service Solahart Jakarta Selatan (081313462267) Dealer Resmi | Page 2
Thermosiphon LCSD and LCSD Free Heat Open Circuit Systems
These systems are suitable for multiple installations. They are not suitable for frost and harsh water regions^.
LCSD and LCSD Free Heat Systems
Model
300 tank
Water Supply
302 system
Tank Model
LCSD Series
300L
LCSD Free Heat
300LF
3
3
Collector model
LCS
No. of collectors
–
–
2
TRV OTP
TPR valve setting
kPa
1000
ECV* setting
kPa
850
Max. supply pressure
with ECV
without ECV
kPa
680
kPa
800
Water Connections
cold
RP¾/20
hot
RP½/15
3**
Storage capacity
litres
300
300
Boost capacity
litres
150
150
*Expansion Control Valve (ECV).
Electric Boost Specifications
Weight empty
kg
81
151
full
kg
381
457
Heating unit type*
2.48
Supply voltage
A - Width*
m
2.43
LCS Collector
Aperture area
m
Dimensions
length
1.87
mm
1937
width
mm
1022
height
mm
77
litres
2.0
kg
30
Capacity
Weight
empty
full
Working pressure
kg
32
kPa
1000
Mirotherm sputtered selective surface
Absorber material
Aluminium
Copper
Number of risers
6
Tray material
base
38mm glasswool blanket
sides
Polyester blanket
Glass
Current
amps
30°C
litres/hour
40°C
litres/hour
50°C
litres/hour
1.8
7
51
38
31
2.4
10
68
52
41
3.6
15
103
77
62
These systems, combined with the TRV OTP system, can be installed with a Solahart
inline gas booster water heater. Refer to the gas booster specification sheet for
further details on the gas booster.
Technical data is subject to change.
Mirotherm® is a registered trademark of Alanod Solar GmbH & Co. KG
^
Harsh water regions – the Solahart warranty may not apply to the water heater if it
is connected to a water supply which: is scaling with a Saturation Index >+0.8, or:
is corrosive with a Saturation Index <-1.0, or; has a Total Dissolved Solids content
>2500 mg/L.
0.7mm aluminium
Insulation material
Rating
kW
Energy Tip: When installing your solar water heater, install
minimum 3 star rated shower roses and flow restrictors to your
taps if you don’t already have them. This will not only save
water but make your solar savings go further.
Absorber surface
Riser material
220 - 240 Volts (50 Hz)
Recovery rate @ 240V and temperature rise of:
* An additional 0.9m should be left on all four sides of the installation for safe
access and servicing.
**TRV OTP is mandatory on these models in Australia and New Zealand.
2
Copper sheath immersion element
3.2mm tempered low iron
Dimensions
A
USE FRAME
MA
XIM
CH
30
510
mm
246
0
510
2460
PIT
mm
UM
MINIMU
M PITCH
10
Solahart Australia Tel: 1300 769 475 www.solahart.com.au
Solahart International Tel: +61 8 9351 4600 www.solahart.com
Reorder: SHB/LCSD SH930LCSD 2013 February
45°