33-1197 Solahart Owner‟s Manual – Thermosiphon Systems - Revision H – Nov 2013
54
INSTALLER’S CHECKLIST
Ensure that the system is installed as directed in this manual
Ensure the system is installed with the correct TILT (hot pipe side higher)
Check that all mechanical fixings are secured
Check that all pipe connections are correctly tightened
Ensure potable water is connected and switched on
Check that the potable water tank is filled
For Closed Circuit systems ensure the closed circuit has been commissioned correctly and is filled with the correct
concentration of Hartgard solution
Ensure that electrical power is switched on (if required)
Ensure the Collector covers are removed
Ensure that any pipe connections through the roof have been sealed correctly
In case of a remote installation make sure that a minimum of ¾” or 22mm pipe is used and that the piping has a
continuous upwards slope towards the tank.
Ensure roof tiles are put back in to position and roof flashing is watertight
Householder instructed on water heater system use
Provide this manual to the householder
SERVICING
To Empty The Water Heater
!
1)
WARNING: THE POTABLE WATER SUPPLY TO THE SYSTEM SHOULD NOT BE SWITCHED OFF
UNTIL THE COLLECTORS ARE SECURELY COVERED BY AN OPAQUE MATERIAL.
For Closed Circuit Series, securely cover the collectors from sunlight with cardboard or other opaque material
BEFORE emptying the water heater.
Turn off the electricity supply.
Flush cold water through the tank to cool both the tank and the closed circuit fluid and turn off water supply.
For Closed Circuit Series, relieve the pressure in the jacket by removing the PR6 or PR200 jacket relief valve.
Extreme care should be taken when removing the valve as the jacket fluid could be at high temperature and under
pressure.
Release the water pressure at the pressure/temperature relief valve by holding the relief arm open.
Disconnect the cold water inlet and allow the water to drain out via a hose fitted to the cold water inlet connection.
Avoid contact with the hot water and ensure that the hose safely discharges hot water away from the roof area.
Hold open the tank relief lever to allow air into the storage tank.
For „L‟ Series only, unscrew and remove the bung plug on the bottom right-hand corner of the right-hand collector.
2)
3)
4)
5)
6)
7)
8)
9)
Note: If required, the tank can be flushed at this stage by removing the 6 bolt element flange and hosing out any sediment.
Anode Replacement
To replace the anode:
1)
Turn off the electricity supply and water supply.
2)
Release the water pressure at the pressure/temperature relief valve by holding the easing gear open.
3)
Drain the cylinder to a level below the anode fitting (see “To Empty the Water Heater” below).
4)
Remove the electrical cover.
5)
Unscrew the anode nut located to the left of the electric element (or burner tube) and withdraw the old anode.
6)
Insert the new anode assembly into the cylinder through the anode socket. Tighten the new anode nut.
7)
Turn on the water supply, dispel air from the tank via a hot water tap or the pressure/temperature relief valve and
then check that the seal on the nut is watertight.
8)
Re-fit the cover and turn on the electricity supply.
!
WARNING: DO NOT TURN POWER ON UNTIL THE WATER HEATER IS FILLED WITH WATER
OR DAMAGE TO THE HEATING ELEMENT WILL RESULT.