Service Center Solahart (081313462267) water heater | Page 36

33-1197 Solahart Owner‟s Manual – Thermosiphon Systems - Revision H – Nov 2013 34 L SYSTEMS Annual performance calculations of Solahart thermosiphon L systems with the L, LC collectors according to EN12976 SolarKeyMark Systems ITW Test Report 11SYS92-01 for the 151L, 151LC (150 tank, 1 collector), 181L, 181LC (180 tank, 1 collector), 221L, 221LC (220 tank, 1 collector), 302L, 302LC (300 tank, 2 collectors) and 443L, 443LC (440 tank, 3 collectors) systems. Qd = energy demand Model Demand QL = solar energy (load) f-sol = solar fraction 59.6°N 49.5°N 46.8°N 38.0°N 151L, 151LC 110 litres / day Qd QL f-sol MJ/a MJ/a % 6107 2712 44.5 5854 2816 48.1 6628 3930 59.3 4545 3504 77.1 151L, 151LC 140 litres / day Qd QL f-sol MJ/a MJ/a % 7772 3031 39.0 7450 3174 42.6 8435 4319 51.2 5784 4095 70.8 151L, 151LC 170 litres / day Qd QL f-sol MJ/a MJ/a % 9438 3048 32.3 9047 3248 35.9 10243 4333 42.3 7024 4418 62.9 151L, 151LC 200 litres / day Qd QL f-sol MJ/a MJ/a % 11103 3053 27.5 10643 3246 30.5 12050 4338 36.0 8263 4594 55.6 59.6°N 49.5°N 46.8°N 38.0°N 181L, 181LC 140 litres / day Qd QL f-sol MJ/a MJ/a % 7772 3334 42.9 7450 3457 46.4 8435 4791 56.8 5784 4361 75.4 181L, 181LC 170 litres / day Qd QL f-sol MJ/a MJ/a % 9438 3671 38.9 9047 3863 42.7 10243 5234 51.1 7024 4973 70.8 181L, 181LC 200 litres / day Qd QL f-sol MJ/a MJ/a % 11103 3697 33.3 10643 3927 36.9 12050 5242 43.5 8263 5313 64.3 181L, 181LC 250 litres / day Qd QL f-sol MJ/a MJ/a % 13879 3706 26.7 13304 3938 29.6 15063 5257 34.9 10329 5609 54.3 59.6°N 49.5°N 46.8°N 38.0°N 221L, 221LC 140 litres / day Qd QL f-sol MJ/a MJ/a % 7772 3047 39.2 7450 3204 43.0 8435 4327 51.3 5784 4101 70.9 221L, 221LC 170 litres / day Qd QL f-sol MJ/a MJ/a % 9438 3284 34.8 9047 3483 38.5 10243 4630 45.2 7024 4614 65.7 221L, 221LC 200 litres / day Qd QL f-sol MJ/a MJ/a % 11103 3475 31.3 10643 3672 34.5 12050 4868 40.4 8263 5040 61.0 221L, 221LC 250 litres / day Qd QL f-sol MJ/a MJ/a % 13879 3484 25.1 13304 3685 27.7 15063 4865 32.3 10329 5226 50.6 Stockholm Wurzburg Davos Athens 59.6°N 49.5°N 46.8°N 38.0°N 302L, 302LC 200 litres / day Qd QL f-sol MJ/a MJ/a % 11103 5230 47.1 10643 5375 50.5 12050 7628 63.3 8263 6610 80.0 302L, 302LC 250 litres / day Qd QL f-sol MJ/a MJ/a % 13879 5871 42.3 13304 6093 45.8 15063 8420 55.9 10329 7695 74.5 302L, 302LC 300 litres / day Qd QL f-sol MJ/a MJ/a % 16655 6146 36.9 15965 6498 40.7 18075 8766 48.5 12395 8490 68.5 302L, 302LC 400 litres / day Qd QL f-sol MJ/a MJ/a % 22206 6195 27.9 21286 6577 30.9 24100 8772 36.4 16526 9271 56.1 Model Demand 443L, 443LC 250 litres / day Qd QL f-sol MJ/a MJ/a % 59.6°N 13879 7217 52.0 49.5°N 13304 7330 55.1 46.8°N 15063 10679 70.9 38.0°N 10329 8821 85.4 443L, 443LC 300 litres / day Qd QL f-sol MJ/a MJ/a % 16655 8027 48.2 15965 8222 51.5 18075 11767 65.1 12395 10077 81.3 443L, 443LC 400 litres / day Qd QL f-sol MJ/a MJ/a % 22206 9327 42.0 21286 9706 45.6 24100 13400 55.6 16526 12262 74.2 443L, 443LC 600 litres / day Qd QL f-sol MJ/a MJ/a % 33309 9526 28.6 31929 10090 31.6 36150 13556 37.5 24789 14204 57.3 Location Stockholm Wurzburg Davos Athens Model Demand Location Stockholm Wurzburg Davos Athens Model Demand Location Stockholm Wurzburg Davos Athens Model Demand Location Location Stockholm Wurzburg Davos Athens Note: The over temperature protection tests have been carried out according to EN12976 with an irradiation higher than 20 MJ/m2/day. An over temperature protection device should be installed in the situation that irradiation this exposure levels could be exceeded.