FILLING AND COMMISSIONING THE CLOSED CIRCUIT
The solar collectors and tank heat exchanger jacket are connected together to create a sealed, closed circuit that is entirely
separate from the potable water in the storage cylinder. The circuit is filled with „Hartgard‟ fluid. Under no circumstances
can any fluids other than „Hartgard‟ be used as the heat transfer fluid. Only potable water can be used in conjunction with
„Hartgard‟. Refer to the section on water quality on Page 3 of this manual. Should the water quality be above these limits,
then distilled or deionised water should be used.
Only Solahart trained and authorised installers are permitted to fill the closed fluid circuit. Refer to your Solahart dealer for
more information. For authorised installers, a special set of instructions and installation tools are provided.
!
WARNING: THE STORAGE TANK MUST BE FILLED WITH WATER BEFORE FILLING THE CLOSED
CIRCUIT.
Systems Installed with an Over Temperature Protection (OTP) System
An Over Temperature Protection system incorporates a HartStat valve. The HartStat valve is a temperature actuated valve
that is designed to close when exposed to high temperatures.
!
WARNING: APART FROM BEING AN OCCUPATIONAL HEALTH AND SAFETY CONCERN TO THE
INSTALLER, IF THE SOLAR COLLECTORS AND HARTSTAT VALVE ARE NOT COVERED DURING THE
COMMISSIONING PROCEDURE OF THE CLOSED CIRCUIT OF A THERMOSIPHON UNIT, IT IS POSSIBLE
FOR THE SOLAR COLLECTORS TO GENERATE ENOUGH HEAT TO CLOSE THE VALVE. THIS WILL
CREATE A VAPOUR LOCK THAT PREVENTS COMPLETE FILLING OF THE CLOSED CIRCUIT.
If the HartStat valve was to close and the closed circuit is only partially filled the solar performance can be severely
reduced resulting in a no hot water complaint. In addition, excessive noise can be generated from the system leading to
possible disturbance and irritation to the householders.
To avoid premature closure of the HartStat valve, the following instructions MUST BE followed during the commissioning
procedure and charging of the closed circuit.
Ensure the collectors are covered with the carton material. If not, securely cover the collectors with an opaque material.
This is to prevent solar gain and heating of the closed circuit fluid during the commissioning procedure.
Cover the HartStat valve with a cloth soaked in cold water. This is to keep the valve as cool as possible and ensure it
remains in the open position during the commissioning procedure.
Fill the system by the siphon method using a known quantity of fluid. Check this volume against the closed circuit volume
required for the system to ensure the correct amount of fluid has been added.
System
Closed circuit
volume
System
Closed circuit
volume
System
Closed circuit
volume
System
Closed circuit
volume
151
181
182
12 litres
13.5 litres
17 litres
221
222
14.5 litres
18 litres
301
302
303
15.5 litres
19 litres
23 litres
443
444
30 litres
34 litres
If the system is unable to take the correct amount of fluid then further investigation will be required to determine if the
HartStat OTP valve has closed or if there is a blockage in the system.
Instructions detailing the closed circuit commissioning process commences on Page 22.