Sequential Controller Specifications: A] Supply Voltage Input Fuse 230VAC 1.5A 24VDC 3A 110VAC 3A B] Pulse Frequency / Range Adjustability: Standard: 2 to 60 seconds 1) 4 to 120 seconds 2) 6 to 180 seconds C] Pulse Duration / Range Adjustability: 20 to 200 milliseconds to 400 milliseconds 2) 100 to 1000 milliseconds Special Requirements: Special Requirements: 1) 40 D] Number of Sequence Steps 2 through 10, adjustable in field (Factory set at 10) 2 through 18, adjustable in field (Factory set at 18) 2 through 40, adjustable in field (Factory set at 40) E] Operating Temperature Range: 00C to 500C F] Repetitive Accuracy on Time Sequence: ± 5% G] Current Rating per Sequence Step: Voltage Max Inrush Current Constant Current 230 VAC 4 Amp. (50 Hz.) 2 Amp. (50 Hz.) 110 VAC 4 Amp. (50 Hz.) 2 Amp. (50 Hz.) H] Special Requirements for Voltages ( DC Kit Type ) : Following variations can be given in 10 channel, 18 channel , 40 Channel as well as with FEEDBACK Types. Input Voltage Output Voltage 230 VAC 24VDC 110 VAC 24VDC 230 VAC 110VAC (NOTE: Solid-state elements require that minimum continuous current per sequence step must not be less than 0.050 amperes. Consult Factory for special rating requirements including operation below 0.050 amperes)