Sequential Controller Specifications:
A]
Supply Voltage Input Fuse
230VAC
1.5A
24VDC
3A
110VAC
3A
B] Pulse Frequency / Range Adjustability: Standard: 2 to 60 seconds
1) 4 to 120 seconds 2) 6 to 180 seconds
C] Pulse Duration / Range Adjustability: 20 to 200 milliseconds
to 400 milliseconds 2) 100 to 1000 milliseconds
Special Requirements:
Special Requirements: 1) 40
D] Number of Sequence Steps 2 through 10, adjustable in field (Factory set at 10) 2 through 18,
adjustable in field (Factory set at 18) 2 through 40, adjustable in field (Factory set at 40)
E] Operating Temperature Range: 00C to 500C
F] Repetitive Accuracy on Time Sequence: ± 5%
G] Current Rating per Sequence Step:
Voltage Max Inrush Current Constant Current
230 VAC 4 Amp. (50 Hz.)
2 Amp. (50 Hz.)
110 VAC 4 Amp. (50 Hz.)
2 Amp. (50 Hz.)
H] Special Requirements for Voltages ( DC Kit Type ) : Following variations can be given in 10
channel, 18 channel , 40 Channel as well as with FEEDBACK Types.
Input Voltage Output Voltage
230 VAC
24VDC
110 VAC
24VDC
230 VAC
110VAC
(NOTE: Solid-state elements require that minimum continuous current per sequence step
must not be less than 0.050 amperes. Consult Factory for special rating requirements
including operation below 0.050 amperes)