Scigazette Monthly Read February issue of Scigazette magazine | Page 36

purpose, this central contact on the PCB is connected to the earth potential. Due to the shield case and the earthed contacts, the arrangement of the signal carrying contacts results in a similar arrangement to that of an X-coded M12 taken out several hundred to a thousand times. In order to round connector. Each pair offer absolute safety to users, the HARTING ix Industrial is of wires are shielded well from their neighbours in a designed and tested for at least 5,000 cycles. Even after separate cable or connector quadrant. This measure this high number of( dis-) connections, all relevant effectively protects against crosstalk and ensures perfect parameters, such as transition and insulation resistance, data transmission.
voltage resistance and the connection and pulling forces, Cooperation remain within the permissible limits.
In response to the challenging and growing demand for Quality and reliability are a top priority at HARTING. To global digitisation technology, the HARTING Technology
meet these requirements, all connectors are subjected to Group from Espelkamp has entered into cooperation with various tests at our in-house, state-of-the-art test the Japanese company HIROSE Electric C. Ltd., Tokyo, in laboratory and are examined using state-of-the-art which both partners have agreed to bundle their strengths equipment. This applies to all environmental simulations, together.
such as various storage situations involving climatic
In the course of global digitisation through the Internet of extremes and corrosive gases, as well as a variety of things and services, the miniaturisation of components and mechanical tests, such as shock and vibration tests, contact interfaces in connection technology is a decisive factor durability and connection and pulling forces, as well as which must be promoted globally. various other test methods. It ' s no problem for our little
" Industry 4.0 as an expression of the Internet of things superhero. He easily passes even the most demanding of needs one thing above all: an Ethernet connection to any shock and vibration tests according to the railway standard Industry 4.0 component," explained Philip Harting, EN 50155. But Captain ix is not merely a
Chairman of the HARTING Technology Group. " The rugged type. He is fast too. international standardisation of new high-performance
For more performance components and infrastructures is an essential prerequisite for market success, and provides security in terms
Transmission bandwidth also plays a role at a time of ever of planning." The Japanese partner HIROSE Electric offers more data suppliers. This is also the case under difficult miniaturised connection solutions for small portable operating conditions, where EMC is an issue. Highdevices such as mobile phones, tablets and cameras. frequency transmission is always subject to the problem of HIROSE Electric has thus contributed to the miniaturisation interference. HARTING offers continuous 360 ° shielding in of and highspeed transmission by electronic devices. this respect. There are no longer any unprotected wires from the cable to the connection point, which can affect a
The result of this cooperation is the development of a new fault-free high-frequency signal. The cable shield is miniaturised and robust Ethernet interface for high data crimped directly to the connector housing with the rates. The ix Industrial! Dimensions, robustness and Cat. 6A
crimped ring and thus has strain relief and continuous performance in combination with the possibility of Power- shield transition. A particular challenge is to effectively over Ethernet( PoE) are examples of successful minimise the interrelation between the individual data miniaturisation, and more of the same is sought. They give pairs with this small design with very close contacts. For the HARTING ix Industrial the potential to assume the great this purpose, a shield case is concealed between the two legacy of the RJ45. A new standard for Industry 4.0 and IoT contact rows in the socket, which effectively prevents applications. For this vision to become a reality, both interrelation between the two opposing contact rows. partners have jointly launched a new standard and have disclosed and standardised this new Ethernet interface in
Furthermore, the new ix Industrial has not 8, but 10 the published IEC / PAS 61076-3-124. contacts. In each row of contacts, the central contact serves as a shield between the two pairs of wires. For this
Scigazette | 37 | February, 2017