SDL ~ Safety Sign Catalogue 2020
S C A F F TA G
SCAFFOLD TAG
The world’s leading scaffold status tagging system is a unique holder and insert
system which ensures instant visibility of your scaffolding status
and helps you effi ciently manage your inspection procedures.
• A Scafftag ® should be fi tted at all legal access points (normally ladder access from
fi rst build to dismantle).
• Holders display a prohibition symbol and the wording “DO NOT USE SCAFFOLD” during erection,
awaiting inspection, failure and dismantle stages.
• Scafftag ® Kit contains: 10 Holders, 20 Standard Inserts and 1 Pen – replacement inserts are sold
separately.
• We recommend that you use the Wallchart and Pocket Guide (semi-rigid PVC) to accompany
your Scafftag ® equipment. These will increase the employee knowledge and encourage the use
of Scafftag ® equipment in their routine.
KIT CONTENTS
SCAFFTAG ® KIT
10 x Holders / 20 x Standard Inserts
1 x Pen
Replacement Inserts sold separately.
STANDARD
INSPECTION
INSERT
Code
SCF01
Description
Price
£58.21
Kit
POCKET GUIDE
HOLDER
Pack of 10 holders comes with a pen
DO NOT
USE
SCAFFOLD
© Copyright Brady Corp Ltd
Tel: +44(0)845 089 4050
www.scafftag.com
Ref. STH
Ref STSI (st)
Code
Qty.
SCF03A
SCF03B
Price
£10.44
£46.95
10
50
Code
SCF28
Price
£48.30
Code
SCF05
Qty.
Price
£5.22
5
vbQOX??VNUNOV??PQYPT??o¢¤ƒ?P
WALLCHART
Code
BLUE BOOK
Price
WC209
Along with the blue book you
will also receive 1 x Scafftag
Holder, sample inserts and
sample posters.
1
3
2
Independent Tied Scaffold
5
£22.75
8
4
12
7
11
9
9
10
6
15
13
13
13
14
Extracts from BS EN 12811-1:20
03, NASC TG 20:05
Work at Height Regulation
s 2005, Construction (H.S.&W.)
Regs 1996
All components must be
undamaged and serviceabl
Tubes: Must not be bent, split,
e
1.
or distorted or corroded.
Boards:
Must not be excessively split,
warped or knotted.
Fittings: Must be regularly serviced
and maintained.
Gin Wheels To be secured on load
bearing couplers S.W.L. Clearly
marked LOAD NOT TO
EXCEED 50 KGS.
2.
Guard Rails (WAHR)
Minimum height of 950mm on working
platforms, secured on the inside
the standards. An intermediate guard
of
rail shall be positioned to limit the
gap to 470mm.
3.
Toeboards Min height to150mm
fixed on all working platforms.
4.
Boarding To be close boarded and
end butted throughout. Overhang
of the boards of any
thickness should not exceed four
times their thickness should not
be less than 50mm e.g. detail on
38mm board min. 50mm - max.
150mm.
Transoms
Maximum spacing 1.2m BS EN12811-1
Tarpaulins To be fixed only to structures
designed for their use.
Standards Centres dependent upon
duty use.
BS 12811-1
Standard
D u t y
L o a d i n g
C e n t r e s
Very Light Duty
Class 1
0.75 kN/m2
2.7m
Light Duty
Class 2
1.50 kN/m2
2.4m
General Purpose
Class 3
2.00 kN/m2
2.1m
Heavy Duty
Class 4
3.00 kN/m2
1.8m
Class 5
4.5 kN/m2
Designed
Class 6
6.0 kN/m2
Designed
8.
Ledgers Centres not to exceed
2.00m, but base lift may be up to
2.7m max. for passage of
pedestrians.
9.
Ties (BS EN 128811-1)
- Types of Ties, Box, Lip, Through,
Reveal & Masonry Anchor
- Class of Ties, Light Duty 3.5kN
in tension
Standard 6.1kN in tension
Heavy Duty 12.2kN in tension
- Layout, on alternate standards
on alterate levels max 4m apart.
- Masonry anchor ties should have
5% tested for pull out.
10.
Ledger Joints Not more than 1/3
into a bay and be staggered throughout
i.e. Not in
adjacent bays or lifts.
11.
Standard Joints Must not occur
at same height.
12.
Standard/Ledgers Fixed with right
angle couplers.
5.
6.
7.
100
As the manufacturer, Scafftag recommend
that in operation it is the responsibility
showing “Safe to Use” and is within
of the scaffold user to ensure the
the inspection dates. We reserve
equipment
the right to alter without prior notice
products. SCAFFTAG Systems and
any specification
Products are registered and copyright
protected.
©Scafftag Ltd. 2006
STORAGE DESIGN LTD
13.
14.
15.
16.
Code
Bracing (BS EN12811-1 & TG 20
: 05) - Ledger, Façade & Plan.
- Ledger bracing should be fixed
at alternate pairs of standards in
all lifts. Note - All working lifts must
unimpeded therefore the ledger
be
bracing must be removed. Basic
design (TG20 : 05) allows for removal
2 No adjacent levels at one time.
of
- Façade bracing,set at between
35° & 55° and shall be fitted at least
every 5 bays.
- Plan bracing, at a maximum of
4 lifts and at intervals of not more
than 10 bays.
Baseplates Generally placed below
standards, and 150mm x 150mm.
Soleplate Use in prescribed circumstances
and no smaller than 1,000cm 2 beneath
any one standard.
Access Hierarchy (WAHR)
1. Staircases,
2. Ladder Access Bays with single
lift ladders
3. Ladder Access Bays with multiple
lift ladders
4. Internal ladder access with a protected
ladder trap
5. External ladder access using
a safety gate.
SCF33
Description
Blue Book
Price
£28.45
Ladders
1
2
3
4
5
Supported on both stiles.
Extend 1.05m above landing point
unless alternate handhold provided.
Inclined at angle of about 75° or
1 : 4 ratio base to height.
Securely tied at head & on a firm
& level base.
Never paint wooden pole ladders
(defects may be hidden).
is
of our
Images for illustration purposes
only
Inspection
Reports