Safety Sign Catalogue 2020 SDL-Safety-Sign-Catalogue-2020 | Page 102

SDL ~ Safety Sign Catalogue 2020 S C A F F TA G SCAFFOLD TAG The world’s leading scaffold status tagging system is a unique holder and insert system which ensures instant visibility of your scaffolding status and helps you effi ciently manage your inspection procedures. • A Scafftag ® should be fi tted at all legal access points (normally ladder access from fi rst build to dismantle). • Holders display a prohibition symbol and the wording “DO NOT USE SCAFFOLD” during erection, awaiting inspection, failure and dismantle stages. • Scafftag ® Kit contains: 10 Holders, 20 Standard Inserts and 1 Pen – replacement inserts are sold separately. • We recommend that you use the Wallchart and Pocket Guide (semi-rigid PVC) to accompany your Scafftag ® equipment. These will increase the employee knowledge and encourage the use of Scafftag ® equipment in their routine. KIT CONTENTS SCAFFTAG ® KIT 10 x Holders / 20 x Standard Inserts 1 x Pen Replacement Inserts sold separately. STANDARD INSPECTION INSERT Code SCF01 Description Price £58.21 Kit POCKET GUIDE HOLDER Pack of 10 holders comes with a pen DO NOT USE SCAFFOLD © Copyright Brady Corp Ltd Tel: +44(0)845 089 4050 www.scafftag.com Ref. STH Ref STSI (st) Code Qty. SCF03A SCF03B Price £10.44 £46.95 10 50 Code SCF28 Price £48.30 Code SCF05 Qty. Price £5.22 5 vbQOX??VNUNOV??PQYPT??o¢¤ƒ?P WALLCHART Code BLUE BOOK Price WC209 Along with the blue book you will also receive 1 x Scafftag Holder, sample inserts and sample posters. 1 3 2 Independent Tied Scaffold 5 £22.75 8 4 12 7 11 9 9 10 6 15 13 13 13 14 Extracts from BS EN 12811-1:20 03, NASC TG 20:05 Work at Height Regulation s 2005, Construction (H.S.&W.) Regs 1996 All components must be undamaged and serviceabl Tubes: Must not be bent, split, e 1. or distorted or corroded. Boards: Must not be excessively split, warped or knotted. Fittings: Must be regularly serviced and maintained. Gin Wheels To be secured on load bearing couplers S.W.L. Clearly marked LOAD NOT TO EXCEED 50 KGS. 2. Guard Rails (WAHR) Minimum height of 950mm on working platforms, secured on the inside the standards. An intermediate guard of rail shall be positioned to limit the gap to 470mm. 3. Toeboards Min height to150mm fixed on all working platforms. 4. Boarding To be close boarded and end butted throughout. Overhang of the boards of any thickness should not exceed four times their thickness should not be less than 50mm e.g. detail on 38mm board min. 50mm - max. 150mm. Transoms Maximum spacing 1.2m BS EN12811-1 Tarpaulins To be fixed only to structures designed for their use. Standards Centres dependent upon duty use. BS 12811-1 Standard D u t y L o a d i n g C e n t r e s Very Light Duty Class 1 0.75 kN/m2 2.7m Light Duty Class 2 1.50 kN/m2 2.4m General Purpose Class 3 2.00 kN/m2 2.1m Heavy Duty Class 4 3.00 kN/m2 1.8m Class 5 4.5 kN/m2 Designed Class 6 6.0 kN/m2 Designed 8. Ledgers Centres not to exceed 2.00m, but base lift may be up to 2.7m max. for passage of pedestrians. 9. Ties (BS EN 128811-1) - Types of Ties, Box, Lip, Through, Reveal & Masonry Anchor - Class of Ties, Light Duty 3.5kN in tension Standard 6.1kN in tension Heavy Duty 12.2kN in tension - Layout, on alternate standards on alterate levels max 4m apart. - Masonry anchor ties should have 5% tested for pull out. 10. Ledger Joints Not more than 1/3 into a bay and be staggered throughout i.e. Not in adjacent bays or lifts. 11. Standard Joints Must not occur at same height. 12. Standard/Ledgers Fixed with right angle couplers. 5. 6. 7. 100 As the manufacturer, Scafftag recommend that in operation it is the responsibility showing “Safe to Use” and is within of the scaffold user to ensure the the inspection dates. We reserve equipment the right to alter without prior notice products. SCAFFTAG Systems and any specification Products are registered and copyright protected. ©Scafftag Ltd. 2006 STORAGE DESIGN LTD 13. 14. 15. 16. Code Bracing (BS EN12811-1 & TG 20 : 05) - Ledger, Façade & Plan. - Ledger bracing should be fixed at alternate pairs of standards in all lifts. Note - All working lifts must unimpeded therefore the ledger be bracing must be removed. Basic design (TG20 : 05) allows for removal 2 No adjacent levels at one time. of - Façade bracing,set at between 35° & 55° and shall be fitted at least every 5 bays. - Plan bracing, at a maximum of 4 lifts and at intervals of not more than 10 bays. Baseplates Generally placed below standards, and 150mm x 150mm. Soleplate Use in prescribed circumstances and no smaller than 1,000cm 2 beneath any one standard. Access Hierarchy (WAHR) 1. Staircases, 2. Ladder Access Bays with single lift ladders 3. Ladder Access Bays with multiple lift ladders 4. Internal ladder access with a protected ladder trap 5. External ladder access using a safety gate. SCF33 Description Blue Book Price £28.45 Ladders 1 2 3 4 5 Supported on both stiles. Extend 1.05m above landing point unless alternate handhold provided. Inclined at angle of about 75° or 1 : 4 ratio base to height. Securely tied at head & on a firm & level base. Never paint wooden pole ladders (defects may be hidden). is of our Images for illustration purposes only Inspection Reports REF WS01 Rev 11/06 TEL:01446772614 www.storage-design.ltd.uk [email protected]