SACOR BUSINESS GROUP-2019 COMPANY CATALOGUE SACOR BUSINESS GROUP 2019 COMPANY CATALOGUE | Page 91
22
dOcKaBle sINGle Gas mONItOr
Interchangeable
“smart” sensors
monitor oxygen or
any one of many
toxic gases
One year datalogging
capacity (minimum)
Standard STEL and
TWA
Docking Station™
compatible
HbCO detection
option available
standards, GasBadge ® Pro provides a lifetime of gas
hazard protection with more features than any other
single gas monitor available. Interchangeable “smart”
sensors enable the GasBadge Pro to be quickly adapted
to monitor unsafe levels of oxygen or any one of the
nitrogen dioxide, sulfur dioxide, chlorine, chlorine dioxide,
phosphine, ammonia, hydrogen cyanide and hydrogen.
GasBadge Pro communicates directly via an infrared
interface to optional accessories like the Docking Station™,
Datalink and infrared printer to further simplify and
automate calibration, function (bump) testing and data
downloading. Standard STEL and TWA readings, and
datalogging of up to one year of survey data are featured
along with an event-logger that records the past 15 alarm
events.
Housed in a rugged enclosure, the monitor is immune to
RF, water resistant and extremely durable. A protective
concussion-proof overmold protects the unit from extreme
abuse in a variety of harsh industrial environments. Its
simple and intuitive four-button navigation allows easy
access to setup, operation and calibration functions.
http://www.indsci.com/GasBadgePro/
SPECIFICATIONS
INSTRUMENT WARRANTY:
Warranted for as long as the instrument is supported by
Industrial Scientific Corporation.
CASE:
Rugged, water-resistant polycarbonate shell with protective
concussion-proof overmold. RFI resistant.
DIMENSIONS:
9.4 cm x 5.08 mm x 2.79 mm (3.7" x 2" x 1.1" )
WEIGhT:
85 g (3 oz.)
SENSORS:
CO, H 2 S, O 2 , NO 2 , SO 2, NH 3 , CI 2 , CIO 2 , PH 3 , HCN, H 2 , CO/H 2 Null
MEASURING RANGES:
CO:
0-1,500 ppm in 1 ppm increments
H 2 S: 0-500 ppm in 0.1 ppm increments
0-30% by volume in 0.1% increments
O 2 :
NO 2 : 0-150 ppm in 0.1 ppm increments
SO 2 : 0-150 ppm in 0.1 ppm increments
NH 3 : 0-500 ppm in 1 ppm increments
0-100 ppm in 0.1 ppm increments
Cl 2 :
ClO 2 : 0-1 ppm in 0.01 ppm increments
PH 3 : 0-10 ppm in 0.01 ppm increments
HCN: 0-30 ppm in 0.1 ppm increments
0-2,000 ppm in 1 ppm increments
H 2 :
DISPLAY:
Custom LCD with graphical icons for easy use
Segmented display for direct gas readings
Backlight for low light conditions
“Go/No Go” display mode
Peak reading indication
ALARMS:
User selectable low and high alarms
Ultra-bright LEDs, loud audible alarm (95 dB) and vibrating alarm
BATTERY RUNTIME:
User replaceable 3V, CR2 Lithium battery, 2,600 hour run time, typical
DATALOGGING:
1 year continuous storage of data.
EVENT-LOGGER:
Continually on. Logs last 15 alarm events, stamping how long ago the
event occurred, the duration of the event, and the peak reading seen
during the event. Event-logger can be viewed on PC or printed directly
from the instrument to an infrared printer.
TEMPERATURE RANGE:
-40º to 60ºC (-40º to 140ºF), typical
hUMIDITY RANGE:
0-99% RH (non-condensing), typical
IP RATING:
Third-party certified IP64
CERTIFICATIONS:
UL/cUL: Class I, Groups A,B,C,D T4; Class II, Groups E,F,G;
CSA:
Class I, Groups A B C D T4; Ex ia IIC T4
ATEX:
Ex ia I/Ex ia IIC T4; Equipment Group and Category: I M1/II 1G
IECEx:
Ex ia I/IIC T4
ANZEx: Ex ia I/IIC T4
INMETRO: BR - Ex ia IIC T4
China Ex: Ex ia I/IIC T4
KOSHA: Ex ia I/IIC T4
SUPPLIED WITh MONITOR:
Attached suspender clip, calibration adapter and tubing, and operating
instructions