Information requirement s
This information includes the results of calculation of t he seasonal energy consumpt ion and efficiency for air
conditioner in regards t o ErP pursuant t o the Commission Regulation(EU) No.206/2012 and No.626/2011.
Information t o ident ify t he model(s) to which the information relates to:
T YPE
:
Indoor unit(s)
Out door unit
Brand
:
:
:
AIR CONDITIONER
SPLIT
WALL-MOUNTED
S1ZMI24908/01
S1ZMA24908/01
SIEMENS
if fuction includes heating : Indicate t he heating season
the information relates to. Indicated values should relate
to one heating season at a time. Include at least t he
heating season 'Average'.
Average
Y
(mandatory)
Function (indicate if present )
cooling
Y
heating
Y
Item
symbol
value
unit
Design load
Pdesignc
7.0
kW
heating/A verage
Pdesignh
5.4
kW
heating/W armer
Pdesignh
x,x
heating/Colder
Pdesignh
x,x
N
Item
symbol
value
unit
SEER
6.1
-
heating/A verage
4.0
-
kW
heating/W armer
SCOP/W
x,x
-
kW
heating/Colder
SCOP/C
x,x
-
symbol
value
unit
Tj = 35℃
Pdc
7.000
kW
Tj = 30℃
Pdc
4.956
kW
Tj = 25℃
Pdc
3.526
Tj = 20℃
Pdc
2.729
cooling
Declared energy efficiency ratio(*), at indoor
temperature 27(19)℃ and out door t emperature T j
symbol
value
unit
Tj = 35℃
EERd
2.63
-
Tj = 30℃
EERd
4.58
-
kW
Tj = 25℃
EERd
7.17
-
kW
Tj = 20℃
EERd
11.71
-
Declared capacity(*) for heating/A verage season, at
indoor temperature 20℃ and out door t emperature T j
symbol
value
unit
Tj = -7℃
Pdh
4.777
kW
Tj = 2℃
Pdh
2.949
Tj = 7℃
Pdh
Tj = 12℃
Pdh
Tj = bivalent
temperature
Pdh
Tj = operating limit
Pdh
Item
Declared coefficient of performance(*)/Average season,
at indoor temperature 20℃ and out door t emperature T j
symbol
value
unit
Tj = -7℃
COPd
2.42
-
kW
Tj = 2℃
COPd
4.07
-
1.929
kW
Tj = 7℃
COPd
5.24
-
1.980
kW
Tj = 12℃
COPd
5.96
-
kW
Tj = bivalent
temperature
COPd
2.42
-
kW
Tj = operating limit
COPd
1.75
-
4.777
5.164
Declared capacity(*) for heating/W armer season, at
indoor temperature 20℃ and out door t emperature T j
Item
Colder
(if designated)
SCOP/A
Declared capacity(*) for cooling, at indoor temperature
27(19)℃ and out door t emperature T j
Item
N
Seasonal efficiency
cooling
Item
Warmer
(if designated)
symbol
value
unit
Tj = 2℃
Pdh
x,x
kW
Tj = 7℃
Pdh
x,x
kW
Tj = 12℃
Pdh
x,x
Tj = bivalent
temperature
Pdh
x,x
Item
Declared coefficient of performance(*)/Warmer season,
at indoor temperature 20℃ and out door t emperature T j
Item
symbol
value
unit
Tj = 2℃
COPd
x,x
-
Tj = 7℃
COPd
x,x
-
kW
Tj = 12℃
COPd
x,x
-
kW
Tj = bivalent
temperature
COPd
x,x
-