Information requirements This information includes the results of calculation of the seasonal energy consumption and efficiency for air conditioner in regards to ErP pursuant to the Commission Regulation(EU) No.206/2013 and No.626/2013. Information to identify the model(s) to which the information relates to: AIR CONDITIONER TYPE : MONO SPLIT WALL-MOUNTED : S1ZMI09911/01 : S1ZMA09911/01 Indoor unit(s) Outdoor unit : SIEMENS Brand cooling Pdesignc 2.8 kW cooling SEER 6.5 - heating/Average Pdesignh 2.4 kW heating/Average SCOP/A 4.0 - heating/Warmer Pdesignh x,x kW heating/Warmer SCOP/W x,x - heating/Colder Pdesignh x,x kW heating/Colder SCOP/C x,x - Declared capacity(*) for cooling, at indoor temperature Declared energy efficiency ratio(*), at indoor 27(19)℃ and outdoor temperature Tj temperature 27(19)℃ and outdoor temperature Tj Item symbol value unit Tj = 35℃ Pdc 2.800 kW Tj = 30℃ Pdc 1.930 kW Tj = 25℃ Pdc 1.304 Tj = 20℃ Pdc 1.304 symbol value unit Tj = 35℃ EERd 3.22 - Tj = 30℃ EERd 5.15 - kW Tj = 25℃ EERd 8.10 - kW Tj = 20℃ EERd 11.24 - Declared capacity(*) for heating/Average season, at indoor temperature 20℃ and outdoor temperature Tj Item symbol value unit Tj = -7℃ Pdh 2.123 kW Tj = 2℃ Pdh 1.338 kW Tj = 7℃ Pdh 0.881 kW Tj = 12℃ Pdh 0.852 Tj = bivalent temperature Pdh Tj = operating limit Pdh value unit Tj = -7℃ COPd 2.76 - Tj = 2℃ COPd 4.13 - Tj = 7℃ COPd 4.74 - kW Tj = 12℃ COPd 5.64 - 2.123 kW Tj = bivalent temperature COPd 2.76 - 1.918 kW Tj = operating limit COPd 2.17 - symbol value unit Tj = 2℃ Pdh x,x kW Tj = 7℃ Pdh x,x Tj = 12℃ Pdh Tj = bivalent temperature Tj = operating limit Item Declared coefficient of performance(*)/Warmer season, at indoor temperature 20℃ and outdoor temperature Tj symbol value unit Tj = 2℃ COPd x,x - kW Tj = 7℃ COPd x,x - x,x kW Tj = 12℃ COPd x,x - Pdh x,x kW Tj = bivalent temperature COPd x,x - Pdh x,x kW Tj = operating limit COPd x,x - Declared capacity(*) for heating/Colder season, at indoor temperature 20℃ and outdoor temperature Tj Item Declared coefficient of performance(*)/Average season, at indoor temperature 20℃ and outdoor temperature Tj symbol Declared capacity(*) for heating/Warmer season, at indoor temperature 20℃ and outdoor temperature Tj Item Item symbol value unit Tj = -7℃ Pdh x,x kW Tj = 2℃ Pdh x,x Tj = 7℃ Pdh Tj = 12℃ Tj = bivalent temperature Item Declared coefficient of performance(*)/Colder season, at indoor temperature 20℃ and outdoor temperature Tj Item symbol value unit Tj = -7℃ COPd x,x - kW Tj = 2℃ COPd x,x - x,x kW Tj = 7℃ COPd x,x - Pdh x,x kW Tj = 12℃ COPd x,x - Pdh x,x kW Tj = bivalent temperature COPd x,x -