Radioprotection No. 60-1 | Page 67

E. Saeedian et al.: Radioprotection 2025, 60( 1), 57 – 64 61
Table 1. ESD estimated for different animals in 20 radiographic examinations
group
Imaging site
Number of animals / adopters
Average Dose( mGy) mean ± SD
( min-max)
1
Abdomen
6
0.34 ± 0.12
( 0.20-0.53)
2
Cranial thoracicpinee
2
0.34 ± 0.06
( 0.29-0.38)
3
Head
2
0.33 ± 0.2
( 0.19-0.47)
4
Limbs
3
0.42 ± 0.17
( 0.23-0.53)
5
Lung
3
0.41 ± 0.05
( 0.36-0.46)
6
Neck
4
0.32 ± 0.09
( 0.24-0.41)
3500
Calibra�on Curve for the Rings
H p( 0.07)( μSv)
3000 2500 2000 1500 1000 500
0 y = 41.147x + 88.328 R ² = 0.995
0
10
20
30
40
50
60
70
80
TL intensity( nC)
Fig. 4. Calibration curve of TLDs used in finger dosimetry( reading of dosimeters based on Hp( 0.07)).
Calibra�on Curves for the Cards
H p( 10)( μSv)
4000 3500 3000 2500 2000 1500 1000 500
0 0 5 10 15 20 25 30 TL intensity( nC)
Fig. 5. Calibration curve of TLDs used in body dosimetry( reading of dosimeters based on Hp( 10)).