Radioprotection No 59-2 | Page 74

M . Keshtkar : Radioprotection 2024 , 59 ( 2 ), 131 – 137 133 Table 1 . CT scanning parameters of two protocols for three age groups . Group age ( years ) Protocol CT protocol parameters
Tube potential ( kVp ) Tube current ( mAs ) Slice thickness ( mm ) Nominal beam width ( mm ) pitch
< 5
RC-CT
80 , 110
52.8 ± 12.9
5
16 1.2
1.25 – 1.5
CD-CT
80 , 110
27.8 ± 9.7
5
16 1.2
1.25 – 1.5
5 –< 10
RC-CT
110 , 130
59.7 ± 10.5
5
16 1.2
1 – 1.5
CD-CT
110 , 130
31.4 ± 11.1
5
16 1.2
1 – 1.5
10 – 15
RC-CT
110 , 130
67.8 ± 14.7
5
16 1.2
1 – 1.5
CD-CT
110 , 130
35.7 ± 13.5
5
16 1.2
1 – 1.5
Table 2 . Demographic data and values of effective diameter . Group age ( years ) Sex CT protocol Number Age ( years ) Effective diameter ( cm ) P value
G1 (< 5 )
Male
RC-CT
13
2.9 ± 1.0
15.1 ± 2.6
0.594
CD-CT
13
2.7 ± 0.9
15.3 ± 2.3
Female
RC-CT
14
3.1 ± 1.1
13.9 ± 1.2
0.841
CD-CT
14
2.9 ± 1.0
14.2 ± 0.9
G2 ( 5 –< 10 )
Male
RC-CT
23
7.7 ± 1.3
19.9 ± 1.9
0.332
CD-CT
23
7.6 ± 1.2
20.5 ± 2.1
Female
RC-CT
21
7.1 ± 1.4
17.9 ± 1.8
0.117
CD-CT
21
7.3 ± 1.1
17.3 ± 1.7
G3 ( 10 – 15 )
Male
RC-CT
29
13.1 ± 1.8
23.8 ± 2.3
0.117
CD-CT
29
13.0 ± 1.5
24.2 ± 2.6
Female
RC-CT
27
12.8 ± 1.7
20.4 ± 2.3
0.472
CD-CT
27
13.0 ± 1.7
19.1 ± 1.7
Table 3 . Data on CTDIvol , DLP , effective dose and SSDE .
Group age ( years ) Dose descriptors ( Mean ± SD ) CTDI vol ( mGy ) DLP ( mGy . cm ) Effective dose ( mSv ) SSDE ( mGy )
RC-CT
CD-CT
RC-CT
CD-CT
RC-CT
CD-CT
RC-CT
CD-CT
G1 (< 5 )
2.4 ± 0.6
1.1 ± 0.4
58.7 ± 14.3
26.7 ± 12.2
1.4 ± 0.6
0.9 ± 0.2
4.5 ± 1.2
2.1 ± 0.5
G2 ( 5 –< 10 )
2.9 ± 0.4
1.3 ± 0.3
75.9 ± 11.8
34.5 ± 9.8
1.8 ± 0.8
1.1 ± 0.2
5.5 ± 1.2
2.5 ± 0.6
G3 ( 10 – 15 )
3.3 ± 0.9
1.5 ± 0.3
87.1 ± 15.3
39.6 ± 12.7
1.9 ± 2.3
1.2 ± 0.3
5.7 ± 2.1
2.6 ± 0.5
Data on dose descriptors such as CTDIvol , DLP , effective dose and SSDE are summarized in Table 3 . The lowest values of CTDI vol were 2.4 ± 0.6 mGy and 1.1 ± 0.4 mGy for RC-CT and CD-CT protocols in the G1 group , respectively . The highest values of CTDI vol were 3.3 ± 0.9 mGy and 1.5 ± 0.3 mGy for RC-CT and CD-CT protocols in the G3 group , respectively .
The lowest values of DLP ( mGy . cm ) were 58.7 ± 14.3 and 26.7 ± 12.2 for RC-CT and CD-CT protocols in the G1 group , respectively . The highest values of DLP ( mGy . cm ) were 87.1 ± 15.3 and 39.6 ± 12.7 for RC-CT and CD-CT protocols in the G3 group , respectively .
The lowest values of effective dose were 1.4 ± 0.6 mSv and 0.9 ± 0.2 mSv for RC-CT and CD-CT protocols in the G1 group , respectively . The highest values of effective dose were
1.9 ± 2.3 mSv and 1.2 ± 0.3 mSv for RC-CT and CD-CT protocols in the G3 group , respectively .
The lowest values of SSDE were 4.5 ± 1.2 mGy and 2.1 ± 0.5 mGy for RC-CT and CD-CT protocols in the G1 group , respectively . The highest values of SSDE were 5.7 ± 2.1 mGy and 2.6 ± 0.5 mGy for RC-CT and CD-CT protocols in the G3 group , respectively . The statistical analysis showed that the SSDE was lower in the CD-CT protocol group compared to the RC-CT protocol group for all three age groups ( P < 0.05 ).
Figure 1 presents organ doses for G1 , G2 , and G3 . For the males , the lungs received the highest organ dose ( 4.27 ± 1.4 mGy ) in the RC-CT protocol of the G3 age group . Also , for the females , the lungs received the highest organ dose ( 3.90 ± 1.23 mGy ) in the RC-CT protocol of the G3 age group .