Radioprotection No 59-1 | Page 31

Z . Mehrabankhoo et al .: Radioprotection 2024 , 59 ( 1 ), 19 – 25 25
Ethical approval Ethical approval was not required .
Informed consent
This article does not contain any studies involving human subjects .
Authors contributions
All authors contributed to various stages of simulations , data analysis , interpretation of results , and manuscript preparation .
Acknowledgments
The author would like to thank the support of the High- Performance Computing Center of the University of Birjand . The results of this study were extracted from the data of a research project under the grant number 1939 , which was financially supported by Semnan University of Medical Sciences ( SEMUMS ).
References
Bozkurt A , Chao TC , Xu XG . 2000 . Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-man anatomical model . Phys Med Biol 45 : 184 – 202 . Denise BP . 2008 . MCNPX User ’ s Manual , Version 2.6.0 . Los Alamos :
Los Alamos National Laboratory . Endo A , Petoussi-Henss N , Zankl M , Bolch WE , Eckerman KF , Herte NE , et al . 2013 . Overview of the ICRP / ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures . Radiat Prot Dosim 161 : 11 – 16 .
Fisher RF , Hintenlang DE . 2014 . Super-size me : adipose tissueequivalent additions for anthropomorphic phantoms . J Appl Clin Med Phys 15 : 306 – 312 .
Han EY , Bolch WE , Eckerman KF . 2006 . Revisions to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema . Health Phys 90 : 337 – 356 .
Geyer AM , Reilly SO , Lee C , Long Dj , Bolch WE . 2014 . The UF / NCI family of hybrid computational phantoms representing the current US population of male and female children , adolescents , and adults — application to CT dosimetry . Phys Med Biol 59 ( 18 ): 5225 – 5242 .
ICRP Publication 60 . 1991 . Recommendations of the International Commission on Radiological Protection . Pergamom : Oxford .
ICRP Publication 74 . 1996 . Conversion Coefficients for use in Radiological Protection Against External Radiation . Pergamom : Oxford .
ICRP Publication 103 . 2007 . Recommendations of the ICRP . Amsterdam : Elsevier .
ICRP Publication 146 . 2020 . Radiological Protection of People and the Environment in the Event of a Large Nuclear Accident : Update of ICRP Publications 109 and 111 . Sage .
ICRPU Publication 60 . 1998 . Fundamental Quantities and Units for Ionizing Radiation . Pergamom : Oxford .
Jamsranjav E , Ito A , Kato Y , Tatebe Y , Takase N , Yoshida S . 2019 . DNA strand breaks induced by fast and thermal neutrons from YAYOI research reactor in the presence and absence of boric acid . Radiat Res 191 : 483 – 489 .
Johnson P , Lee C , Johnson K , Siragusa D , Bolch WE . 2009 . The influence of patient size on dose conversion coefficients : a hybrid phantom study for adult cardiac catheterization . Phys Med Biol 54 ( 12 ): 3613 – 3629 .
Karimi-Shahri K , Rafat-Motavalli L , Miri-Hakimabad H . 2013 . Can the same dose data be estimated from phantoms with different anatomies ? Radioprotection 48 : 527 – 544 .
Karimi-Shahri K . 2020 . Estimation of the effective dose of radiation workers : optimization based on the weight percentile . Health Phys 119 : 273 – 279 .
Kim CH , Chichkov I , Reece WD . 2003 . Effect of torso adipose tissue thickness on effective dose in a broad parallel photon beam . Health Phys 85 : 471 – 475 .
Li G , Gao J , Liu ZG , Tao YL , Xu BQ , Tu ZW , Xia YF . 2014 . Influence of pretreatment ideal body weight percentile and albumin on prognosis of nasopharyngeal carcinoma : long-term outcomes of 512 patients from a single institution . Head & Neck 36 ( 5 ): 660 – 666 .
McHale SR , Walker ER . 2021 . Dose conversion coefficients from monoenergetic neutrons computed with the MC NP6 . 2 Code in the VIP-Man Phantom . Radiat Prot Dosim 193 : 105 – 123 .
Miri HH , Rafat ML , Karimi SK . 2009 . Assessment of neutron fluence to organ dose conversion coefficients in the ORNL analytical adult phantom . J Radial Prot 29 : 51 – 60 .
Miri HH , Rafat ML , Karimi SK . 2012 . Different effective dose conversion coefficients for monoenergetic neutron fluence from 10 �9 MeV to 20 MeV-A methodological comparative study . Radioprotection 47 : 271 – 284 .
Xu XG , Eckerman KF . 2010 . Computational phantoms for radiation dosimetry : a 40-Year history of evolution . Handbook of Anatomical Models for Radiation Dosimetry 1 : 3 – 41 .
Cite this article as : Mehrabankhoo Z , Behmadi M , Karimi-Shahri K . 2024 . Rapid assessment of dose for large-scale individual : a feasibility study . Radioprotection 59 ( 1 ): 19 – 25