380 M. Zhou et al.: Radioprotection 2025, 60( 4), 373 – 381
Acknowledgments
This project was supported by Réseau de Transport d’ Électricité. Funding
This research did not receive any specific funding.
Conflicts of interest
The authors declare that they have no conflict of interest.
Data availability statement
The research data associated with this article are included within the article.
Author contribution statement
All authors have read and agreed to the published version of the manuscript.
Ethics approval
Ethical approval was not required.
Informed consent
Not applicable.
Reference
Badger J, Taylor P, Swain I. 2017. The safety of electrical stimulation in patients with pacemakers and implantable cardioverter defibrillators: a systematic review. J Rehabilit Assist Technolog Eng 4: 205566831774549.
Driessen S, Napp A, Schmiedchen K, Kraus T, Stunder D. 2019 Electromagnetic interference in cardiac electronic implants caused by novel electrical appliances emitting electromagnetic fields in the intermediate frequency range: a systematic review. EP Europace 21: 219 – 229.
Egger F, Hofer C, Hammerle FP, Lofler S, Nurnberg M, Fiedler L, Kriz R, Kern H, Huber K. 2019. Influence of electrical stimulation therapy on permanent pacemaker function, Wiener klinische Wochenschrift 131( 13 – 14): 313 – 320.
Gerçek C, Kourtiche D, Nadi M, Magne I, Schmitt P, Roth P, Souques M. 2020. Phantom model testing of active implantable cardiac devices at 50 / 60 Hz electric field. Bioelectromagnetics 41: 136 – 147.
Gustrau F, Bahr A, Goltz S, Eggert S. 2002. Active medical implants and occupational safety- measurement and numerical calculation of interference voltage. Biomedizinische Technik. Biomed Eng 47: 656 – 659.
Institute of Electrical and Electronics Engineers( IEEE). 2019. IEEE standard for safety levels with respect to human exposure to electric, magnetic, and electromagnetic fields, 0 Hz to 300 GHz, IEEE-C95.1.
International Commission on Non-Ionizing Radiation Protection( ICNIRP). 2010. Guidelines for limiting exposure to time-varying electric and magnetic fields( 1 Hz to 100 kHz). Health Phys 99: 818 – 836.
Lennerz C, Schaarschmidt C, Blažek P, Knoll K, Kottmaier M, Reents T, Bourier F, Lengauer S, Popa M, Wimbauer K, Bahlke F, Krafft H, Englert F, Friedrich L, Schunkert H, Hessling G, Deisenhofer I, Kolb C, O’ Connor M. 2023 High-power chargers for electric vehicles: are they safe for patients with pacemakers and defibrillators? Europace 25: euad042.
Magne I, Souques M. 2012. Risk assessment for implanted cardiac defibrillator workers occupationally exposed to electromagnetic fields, in International Symposium on Electromagnetic Compatibility- EMC EUROPE, 2012, Rome, Italy, pp. 1 – 5.
Magne I, Souques M, Courouve L, Duburcq A, Remy E, Cabanes PA, 2020. Exposure of adults to extremely low frequency magnetic field in France: results of the EXPERS study. Radioprotection 55: 39-50.
Mattei E, Lucano E, Censi F, Triventi M, Calcagnini G. 2016. Provocative testing for the assessment of the electromagnetic interference of RFID and NFC readers on implantable pacemaker. IEEE Trans Electromagn Compatib 58: 314 – 322.
Mattei E, Calcagnini G, Censi F, Pinto I, Bogi A, Falsaperla R. 2019. Workers with active implantable medical devices exposed to EMF: in vitro test for the risk assessment. Environments 6: 119.
Mattei E, Censi F, Calcagnini G, Falsaperla R. 2021. Workers with cardiac AIMD exposed to EMF: methods and case studies for risk analysis in the framework of the European regulations. Int J Environ Res Public Health 18: 9709.
Napp A, Stunder D, Maytin M, Kraus T, Marx N, Driessen S. 2015. Are patients with cardiac implants protected against electromagnetic interference in daily life and occupational environment? Eur Heart J 36: 1798 – 1804.
Nazarian S, Roguin A, Zviman MM, Lardo AC, Dickfeld TL, Calkins H, Weiss RG, Berger RD, Bluemke DA, Halperin HR, 2006. Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 Tesla. Circulation 114: 1277 – 1284.
Nordbeck P, Weiss I, Ehses P, Ritter O, Warmuth M, Fidler F, Herold V, Jakob PM, Ladd ME, Quick HH, Bauer WR, 2009. Measuring RF,-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads. Magn Reson Med 61: 570 – 578.
Seckler T, Jagielski K, Stunder D. 2015. Assessment of electromagnetic interference with active cardiovascular implantable electronic devices( CIEDs) caused by the Qi A13 design wireless charging board. Int J Environ Res Public Health 12: 5886 – 5904.
Seidman SJ, Guag J, Beard B, Arp Z. 2021. Static magnetic field measurements of smart phones and watches and applicability to triggering magnet modes in implantable pacemakers and implantable cardioverter-defibrillators. Heart Rhythm 18: 1741 – 1744.
Seidman SJ, Pantchenko O, Tennakoon D. 2014. Design of unique simulators to evaluate medical device susceptibility to radio frequency identification exposure. IEEE Electromagn Compat Mag 3: 70 – 74.
Strom JB, Whelan JB, Shen C, Zheng SQ, Mortele KJ, Kramer DB, 2017. Safety and utility of magnetic resonance imaging in patients with cardiac implantable electronic devices. Heart Rhythm 14: 1138 – 1144.