RACA Journal September 2020 | Page 15

International News Continued from page 11 • The role of HEPA filters in buildings outside of healthcare settings in preventing transmission of infectious diseases is unclear. A modelling study of the infection risk from SARS- CoV-1, the virus causing SARS, conferred by three types of ventilation systems in relatively large commercial aeroplanes, found that mixing ventilation systems had the highest risk and conventional displacement systems had the lowest risk. • Well-maintained HVAC systems, including air-conditioning units, securely filter large droplets containing SARS-CoV-2. It is possible for COVID-19 aerosols (small droplets and droplet nuclei) to spread through HVAC systems within a building or vehicle and stand-alone air-conditioning units if air is recirculated. • Air flow generated by air-conditioning units may facilitate the spread of droplets excreted by infected people longer distances within indoor spaces. • HVAC systems may have a complementary role in decreasing transmission in indoor spaces by increasing the rate of air change, decreasing recirculation of air and increasing the use of outdoor air. GUIDANCE Infection control measures with proven evidence for reducing the risk of SARS-CoV-2 transmission should be emphasised. Organisers and administrators responsible for gatherings and critical infrastructure settings should provide guidance material to participants regarding the application of other preventive measures, including: • Physical distancing • Meticulous hand hygiene • Respiratory etiquette • Appropriate use of face masks, if required for staff, and in areas where physical distancing cannot be maintained due to structural or functional impediments. Building administrators should maintain heating, ventilation, and air-conditioning systems according to the manufacturer’s current instructions, particularly in relation to the cleaning and changing of filters. There is no benefit or need for additional maintenance cycles in connection with COVID-19. Energy-saving settings, such as demand-controlled ventilation controlled by a timer or CO₂ detectors, should be avoided. Consideration should be given to extending the operating times of HVAC before and after the regular periods of use. Direct air flow should be diverted away from groups of individuals to avoid pathogen dispersion from infected subjects and transmission. Organisers and administrators responsible for gatherings and critical infrastructure settings should explore Pinterest options with the assistance of their technical/maintenance teams to avoid the use of air recirculation as much as possible. They should consider reviewing their procedures for the use of recirculation in HVAC systems based on information provided by the manufacturer or, if unavailable, seeking advice from the manufacturer. The minimum number of air exchanges per hour, in accordance with the applicable building regulations, should be ensured at all times. Increasing the number of air exchanges per hour will reduce the risk of transmission in closed spaces. This may be achieved by natural or mechanical ventilation, depending on the setting. The application of the above guidance should be in accordance with national and local regulations (for example, building regulations, health and safety regulations) and appropriate to local conditions. Technical specifications and standards for mechanical ventilation systems to reduce the risk of COVID-19 transmission in indoor spaces still need to be defined on the basis of scientific studies that are tuned to COVID19 research developments that are continuous. The technical specifications will need to be defined for categories of room or location type, taking into account the room size, the degree of enclosure and non-mechanical ventilation, and the probable purpose for which the room will be used. Moreover, options should be provided for protected buildings that be subject to engineering modifications. The technical standards should ideally recommend minimum criteria to be met in order for authorities to permit the intended use of an enclosed space. The technical specifications regarding the logistical arrangement of enclosed spaces, including the physical placement of mechanical ventilation systems, also need to be informed by scientific evidence and technical expertise, so as to minimise the risk of transmission. These specifications will also need to take into account the expected number of users, the types of user and the user activity. For example, in supermarkets, cashiers and customers have different levels of mobility and durations of occupancy. As a general principle, mechanical ventilation should be arranged to minimise the direction of sustained air flow for stationary persons. RACA The study shows that the direction of airflow also plays a major role in buildings catering to many occupants and infection rates. www.hvacronline.co.za RACA Journal I September 2020 13