Pulse Jet valve Dust collector valve | Page 4

Dust Collector Valve Operation : Maniks pulse valves are functioned by integral solenoid pilot operator. The Trapped air above pulse valve diaphragm is immediately used up causing fast opening of diaphragm valve, When the valve is energized. Air comes out through bleed hole of main pulse valve to balance the diaphragm pressure and immediately closes the valve, when the pilot valve is de-energized. Duty Cycle:The possessing duty time cycle for ac voltage is 20% and for DC voltage is 10 %. This indicates energized time is maximum 1/5th of de-energized time for AC and 1/10th for DC voltage. Installation Process:Dust Collector Pulse Valve can be mounted in any position for smooth operation. However good engineering practice is to stay away from scale and concentrated water entering valve body for trouble free performance, Industry standard end connections of BSP are provided. Dust Collector Repair Kit: Maniks offers a special service called Dust Collector Repair Kit to the Organization whose dust collector system is not working efficiently. So we repair current system parts of dust collector systems and renovate your inoperative valves and assure operating reliability and quality as good as new.