Dust Collector Valve Operation :
Maniks pulse valves are functioned by integral solenoid pilot operator. The Trapped air above
pulse valve diaphragm is immediately used up causing fast opening of diaphragm valve, When
the valve is energized. Air comes out through bleed hole of main pulse valve to balance the
diaphragm pressure and immediately closes the valve, when the pilot valve is de-energized.
Duty Cycle:The possessing duty time cycle for ac voltage is 20% and for DC voltage is 10 %. This
indicates energized time is maximum 1/5th of de-energized time for AC and 1/10th for DC
voltage.
Installation Process:Dust Collector Pulse Valve can be mounted in any position for smooth
operation. However good engineering practice is to stay away from scale and concentrated
water entering valve body for trouble free performance, Industry standard end connections of
BSP are provided.
Dust Collector Repair Kit:
Maniks offers a special service called Dust Collector Repair Kit to the Organization whose dust
collector system is not working efficiently. So we repair current system parts of dust collector
systems and renovate your inoperative valves and assure operating reliability and quality as
good as new.