PROFIS Design Guide: US-EN Summer 2021 | Page 118

PART 3 TENSION LOAD

Side-Face Blowout Failure
Calculations N sb
Calculations ACI 318-14 Chapter 17 Provision Comments for PROFIS Engineering single anchor in tension
N sb
17.4.4.1 For a single headed anchor with deep embedment close to an edge ( h ef > 2.5c a1
), the nominal side-face blowout strength , N sb , shall not exceed
N sb
= 160c a1
A brg λ a f ́c ( 17.4.4.1 )
If c a2 for the single headed anchor is less than 3c a1
, the value of N sb shall be multiplied by the factor
( 1 + c a2
/ c a1 )/ 4 , where 1.0 < c a2
/ c a1
< 3.0 . PROFIS Engineering calculation for Nsb :
N sb
= 160 α corner c a1
A brg λ a f ́c
PROFIS Engineering bearing area values ( A brg ) for the cast-in anchors in its portfolio .
MATERIAL SPECIFICATION
AWS D1.1 Type B Headed Stud
" ASTM F1554 Headed Bolt Gr . 36 , Gr . 55 , Gr . 105 "
Diameter ( d 0
) ( in )
Bearing area ( A brg in 2 ) welded headed stud
Bearing area ( A brg in 2 ) square head bolt
Bearing area ( A brg in 2 ) heavy square bolt
Bearing area ( A brg in 2 ) hex head bolt
Bearing area ( A brg in 2 ) heavy hex head bolt
0.500
0.589
0.625
0.920
0.750
0.785
0.875
0.884
0.500
0.464
0.569
0.291
0.467
0.625
0.693
0.822
0.454
0.671
0.750
0.824
1.210
0.654
0.911
0.875
1.121
1.465
0.891
1.188
1.000
1.465
1.855
1.163
1.501
1.125
1.854
2.291
1.472
1.851
1.250
2.228
2.773
1.817
2.237
1.375
2.769
3.300
2.199
2.659
1.500
3.295
3.873
2.617
3.118
1.750
4.144
2.000
5.316
17.2.6 Modification factor λ a for lightweight concrete shall be taken as :
Cast-in and undercut anchor concrete failure ............................ 1.0 λ where λ is determined in accordance with 19.2.4 .
17.2.7 The values of f ́c used for calculation purposes in this chapter shall not exceed 10,000 psi for cast-in anchors ………………
17.7.1 Unless determined in accordance with 17.7.4 , minimum center-to-center spacing of anchors shall be 4d a for cast-in anchors that will not be torqued , and 6d a for torqued cast-in anchors …………………….
17.7.2 Unless determined in accordance with 17.7.4 , minimum edge distances for cast-in anchors that will not be torqued shall be based on specified cover requirements for reinforcement in 20.6.1 . For cast-in anchors that will be torqued , the minimum edge distances shall be 6d a
.
PROFIS Engineering calculates side-face blowout when the anchor effective embedment depth ( h ef
) is greater than 2.5 times the nearest fixed edge ( c a1
). The applied tension load creates lateral bursting stresses at the head of the anchor which cause the concrete to “ blow out ” at the face of the fixed edge . Side-face blowout is a possible failure mode for cast-in anchors and post-installed undercut anchors ; however , PROFIS Engineering does not consider side-face blowout for the HDA-P and HDA-T undercut anchors in its portfolio because it will not be a controlling tension failure mode for these anchors .
When modeling a single anchor in tension , the side-face blowout strength for a single anchor ( N sb
) is calculated , and modified by the factor ( 1 + c a2
/ c a1 )/ 4 if a corner formed by the fixed edge distances c a1 and c a2 exists . PROFIS Engineering designates this factor “ α corner ”. The parameter c a2 corresponds to the fixed edge perpendicular to c a1
.
PROFIS Engineering only performs side-face blowout calculations for the cast-in anchors in its portfolio . This portfolio is as follows :
• AWS D1.1 Type B headed studs : ( 1 / 2 ” – 7 / 8 ” nominal diameter )
• ASTM F1554 hex head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” – 1 1 / 2 ” nominal diameter )
• ASTM F1554 heavy hex head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” – 2 ” nominal diameter )
• ASTM F1554 square head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” – 1 1 / 2 ” nominal diameter )
• ASTM F1554 heavy square head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” – 1 1 / 2 ” nominal diameter )
The software uses the minimum spacing requirements given in Section 17.7.1 and the minimum edge distance requirements given in Section 17.7.2 for cast-in anchors .
λ a is a modification factor for lightweight concrete . PROFIS Engineering uses the provisions of Sections 17.2.6 and 19.2.4 to calculate λ a
.
f ́c corresponds to the concrete compressive strength being modeled . PROFIS Engineering uses the provisions of Section 17.2.7 to calculate f ́c .
Reference the Variables section of the report for more information on the parameters c a1
, c a2 , A brg
, λ a
, f ́c and s .
Reference the Equations section of the report for more information on the parameter N sb
.
Reference the Equations and Calculations section of the report for more information on the parameter α corner
.
118 NORTH AMERICAN PROFIS ENGINEERING ANCHORING TO CONCRETE DESIGN GUIDE — ACI 318-14 Provisions