PROFIS Design Guide: US-EN Summer 2021 | Page 103

PART 3 TENSION LOAD

Side-Face Blowout Failure
Equation N sb = 160 α corner c a1
Equation ACI 318-14 Chapter 17 Provision Comments for PROFIS Engineering
N sb
= 160 α corner c a1
A brg λ a f ́c
17.4.4.1 For a single headed anchor with deep embedment close to an edge ( h ef > 2.5c a1
), the nominal side-face blowout strength , N sb , shall not exceed
N sb
= 160c a1
A brg λ a f ́c ( 17.4.4.1 )
If c a2 for the single headed anchor is less than 3c a1
, the value of N sb shall be multiplied by the factor
( 1 + c a2
/ c a1 )/ 4 , where 1.0 < c a2
/ c a1 < 3.0 .
PROFIS Engineering permits h ef -values ranging between 4d anchor and 25 ” to be input for the cast-in anchors in its portfolio . PROFIS Engineering bearing area values ( A brg
) for the cast-in anchors in its portfolio .
Profis Engineering cast-in anchor portfolios for bearing area ( A brg ).
MATERIAL SPECIFICATION
AWS D1.1 Type B Headed Stud
" ASTM F1554 Headed Bolt Gr . 36 , Gr . 55 , Gr . 105 "
Diameter ( d 0
) ( in )
Bearing area ( A brg in 2 ) welded headed stud
Bearing area ( A brg in 2 ) square head bolt
Bearing area ( A brg in 2 ) heavy square bolt
Bearing area ( A brg in 2 ) hex head bolt
Bearing area ( A brg in 2 ) heavy hex head bolt
0.500
0.589
0.625
0.920
0.750
0.785
0.875
0.884
0.500
0.464
0.569
0.291
0.467
0.625
0.693
0.822
0.454
0.671
0.750
0.824
1.210
0.654
0.911
0.875
1.121
1.465
0.891
1.188
1.000
1.465
1.855
1.163
1.501
1.125
1.854
2.291
1.472
1.851
1.250
2.228
2.773
1.817
2.237
1.375
2.769
3.300
2.199
2.659
1.500
3.295
3.873
2.617
3.118
1.750
4.144
2.000
5.316
17.2.6 Modification factor λ a for lightweight concrete shall be taken as :
Cast-in and undercut anchor concrete failure ……………….…. 1.0 λ where λ is determined in accordance with 19.2.4 .
17.2.7 The values of f ́c used for calculation purposes in this chapter shall not exceed 10,000 psi for cast-in anchors ………………
Side-face blowout is a tension failure mode that can occur when anchors are installed at a “ deep ” embedment ( h ef
> 2.5c a1 ), near a fixed edge ( c a1
). In lieu of concrete breakout or pullout occurring , the applied tension load creates lateral bursting stresses at the head of the anchor which cause the concrete to “ blow out ” at the face of the fixed edge . PROFIS Engineering assumes the parameter
h ef corresponds to the embedded portion of the anchor that is “ effective ” in transferring tension load from the anchor into the concrete . The parameter c a1 corresponds to the nearest fixed edge , i . e . the edge where side-face blowout is assumed to occur .
Side-face blowout is a possible failure mode for cast-in anchors . Splitting failure , rather than side-face blowout , is a more common failure mode for post-installed anchors ; however , side-face blowout could possibly occur with undercut anchors . PROFIS Engineering does not consider side-face blowout for the HDA-P and HDA-T undercut anchors in its portfolio because it will not be a controlling tension failure mode for these anchors . PROFIS Engineering only performs side-face blowout calculations for the cast-in anchors in its portfolio .
When modeling a single anchor in tension , the side-face blowout strength for a single anchor ( N sb
) is calculated , and modified by the factor ( 1 + c a2
/ c a1 )/ 4 if a corner formed by the fixed edge distances c a1 and c a2 exists . PROFIS Engineering designates this factor “ α corner ”. The parameter c a2 corresponds to the fixed edge perpendicular to c a1
.
The PROFIS Engineering cast-in anchor portfolio is as follows :
• AWS D1.1 Type B headed studs : ( 1 / 2 ” – 7 / 8 ” nominal diameter )
• ASTM F1554 hex head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” – 1 1 / 2 ” nominal diameter )
• ASTM F1554 heavy hex head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” – 2 ” nominal diameter )
• ASTM F1554 square head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” – 1 1 / 2 ” nominal diameter )
• ASTM F1554 heavy square head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” – 1 1 / 2 ” nominal diameter ) λ a is a modification factor for lightweight concrete . PROFIS Engineering uses the provisions of Sections 17.2.6 and 19.2.4 to calculate λ a
.
f ́c corresponds to the concrete compressive strength being modeled . PROFIS Engineering uses the provisions of Section 17.2.7 to calculate f ́c .
Reference the Variables section of the report for more information on the parameters c a1
, c a2 , A brg
, λ a
, and f ́c .
Reference the Calculations section of the report for more information on the parameters α corner and N sb
.
103 NORTH AMERICAN PROFIS ENGINEERING ANCHORING TO CONCRETE DESIGN GUIDE — ACI 318-14 Provisions