PROFIS Design Guide - AC 318-19 July 2022 | Page 333

2.0 SHEAR

2.5 Steel Failure with Lever Arm
Results ϕ steel
Results ETAG 001 Annex C Provision Comments for PROFIS Engineering
ϕ steel
5.2.3.2 Steel failure b ) Shear load with lever arm
The characteristic resistance of an anchor , VRk , s , is given by Equation ( 5.5 ).
V Rk , s
= α M M Rk , s [ N ] ( 5.5 ) l PROFIS Engineering calculations for shear resistance of an anchor subjected to bending :
ϕV M = ϕ ( α M )/ L modified ETAG 001 Equation ( 5 . 5 ) s M s b
ACI 318-19 Chapter 17 provisions and ICC-ES data for ϕ-factors 17.5.3 Strength reduction factor ϕ for anchors in concrete shall in accordance with Tables 17.5.3 ( a )……………………..
Table 17.5.3 ( a ) Anchor strength governed by steel
Type of steel element
Strength reduction factor ϕ
Tension ( steel )
Shear ( steel )
Ductile
0.75
0.65
Brittle
0.65
0.60
PROFIS Engineering cast-in-place anchor portfolio .
• AWS D1.1 : 1 / 2 ” – 7 / 8 ” diameters
• hex head , square head , heavy square head : 1 / 2 ” – 1-1 / 2 ” diameters
• heavy hex head : 1 / 2 ” – 2 ” diameters
MATERIAL SPECIFICATION
AES D1.1
ASTM F 1554
ASTM F 1554
GRADE OR TYPE
DIAMETER ( d 0
) ( in )
TENSILE STRENGTH ( ƒ uta
) ( ksi )
YIELD STRENGTH
( ƒ ya ) ( ksi )
GROSS AREA ( in 2 )
55
2.000
75
55
3.142
2.500
105
0.500
125
105
0.196
0.142
105
0.625
125
105
0.307
0.226
105
0.750
125
105
0.442
0.334
105
0.875
125
105
0.601
0.462
105
1.000
125
105
0.785
0.606
ASTM F 1554
105
1.125
125
105
0.994
0.763
105
1.250
125
105
1.227
0.969
105
1.375
125
105
1.485
1.160
105
1.500
125
105
1.767
1.410
105
1.750
125
105
2.405
1.900
105
2.000
125
105
3.142
2.500
333
NORTH AMERICAN PROFIS ENGINEERING ANCHORING TO CONCRETE DESIGN GUIDE — ACI 318-19 Provisions
EFFECTIVE AREA ( A se
)
( in 2 )
B
0.500
65
51
0.196
B
0.625
65
51
0.307
B
0.750
65
51
0.442
B
0.875
65
51
0.601
36
0.500
58
36
0.196
0.142
36
0.625
58
36
0.307
0.226
36
0.750
58
36
0.442
0.334
36
0.875
58
36
0.601
0.462
36
1.000
58
36
0.785
0.606
36
1.125
58
36
0.994
0.763
36
1.250
58
36
1.227
0.969
36
1.375
58
36
1.485
1.160
36
1.500
58
36
1.767
1.410
36
1.750
58
36
2.405
1.900
36
2.000
58
36
3.142
2.500
55
0.500
75
55
0.196
0.142
55
0.625
75
55
0.307
0.226
55
0.750
75
55
0.442
0.334
55
0.875
75
55
0.601
0.462
55
1.000
75
55
0.785
0.606
55
1.125
75
55
0.994
0.763
55
1.250
75
55
1.227
0.969
55
1.375
75
55
1.485
1.160
55
1.500
75
55
1.767
1.410
55
1.750
75
55
2.405
1.900
PROFIS Engineering uses the provisions given in the European Technical Approval Guideline ( ETAG ) titled ETAG 001 Metal Anchors for Use in Concrete Annex C : Design Methods for Anchorages to consider bolt bending as a possible steel failure mode in shear . When a standoff condition exists for an anchorage , an applied shear load can create bending in the anchors . A shear resistance ( V Rk , s
) for the anchor element is calculated per ETAG Equation ( 5.5 ). ACI 318 anchoringto-concrete provisions require calculation of a “ nominal strength ” which is then multiplied by a strength reduction factor ( s ) ( ϕ-factor ) to obtain a “ design strength ”. The parameter “ V sM
” in PROFIS Engineering corresponds to the “ nominal shear strength ” with respect to bending , and is calculated as follows :
V s
M
= ( α M
M s
)/ L b
The parameter “ ϕV sM
” in PROFIS Engineering corresponds to the “ design shear strength ” with respect to bending , and is calculated as follows :
ϕV s
M
= ϕ [( α M
M s
)/ L b ].
Therefore , the PROFIS Engineering parameter “ ϕV sM ”, corresponds to the parameter “ V Rk , s
” in Equation ( 5.5 ). PROFIS Engineering designates the ϕ-factor corresponding to steel failure “ ϕ steel
”.
When designing cast-in-place anchors , PROFIS Engineering uses the ϕ-factors given in ACI 318-19 Table 17.5.3 ( a ). The ϕ steel
-values for the cast-in-place anchors in the PROFIS Engineering portfolio correspond to the ϕ-factors given in Table 17.5.3 ( a ) for ductile steel elements . In the absence of product-specific data , the ϕ-factors in Table 17.5.3 ( a ) can be used as guide values for post-installed anchors ; however , ϕ-factors derived from product-specific testing should always be used for the actual design of post-installed anchors .
Post-installed mechanical anchors can be qualified for recognition under the International Building Code via testing per the ICC-ES acceptance criteria AC193 in conjunction with the ACI standard ACI 355.2 . Post-installed adhesive anchor systems can be qualified for recognition under the International Building Code via testing per the ICC-ES acceptance criteria AC308 in conjunction with the ACI standard ACI 355.4 . PROFIS Engineering uses the ϕ-factors derived from AC193 / ACI 355.2 or AC308 / ACI 355.4 testing , as given in the ICC-ES evaluation report ( ESR ) for the anchor . The ϕ-factors in the ESR correspond to the ACI 318 ϕ-factors for “ ductile steel element ” and “ brittle steel element ”, as determined by the product testing and material properties for a specific anchor element .
Reference the Results section of the report for more information on the following PROFIS Engineering parameters .
V sM
: nominal shear strength ( resistance ) for bending
ϕV sM
: design shear strength ( resistance ) for bending