1.0 TENSION
1.5 Steel Failure Mode
Results N sa
Results ACI 318-19 Chapter 17 Provision Comments for PROFIS Engineering
N sa
17.6.1.1 Nominal strength of anchors in tension as governed by the steel , N sa
, shall be evaluated based on the properties of the anchor material and the physical dimensions of the anchors .
17.6.1.2 Nominal steel strength of an anchor in tension , N sa , shall be calculated by
N sa
= A se , N ƒ uta
( 17.6.1.2 ) where A se , N is the effective cross-sectional area of an anchor in tension , in . 2 , and ƒ uta used for calculations shall not exceed either 1.9ƒ ya or 125,000 psi . PROFIS Engineering cast-in-place anchor portfolio parameters A se , N and ƒ uta , which are used to calculate N sa per Eq . ( 17.6.1.2 ).
ACI 318-19 Chapter 2 defines the parameter N sa as follows : “ nominal strength of a single anchor or individual anchor in a group of anchors in tension as governed by the steel strength ”.
N sa is always calculated for a single anchor when designing with the provisions of ACI 318-19 .
For cast-in-place anchors , PROFIS Engineering calculates N sa using Equation ( 17.6.1.2 ). The table to the left shows the cast-in-place anchor portfolio in PROFIS Engineering , and the parameters that are used to calculate N sa for a given anchor type and diameter .
MATERIAL SPECIFICATION
AES D1.1
ASTM F 1554
ASTM F 1554
ASTM F 1554
GRADE OR TYPE
DIAMETER ( d 0
) ( in )
TENSILE STRENGTH ( ƒ uta
) ( ksi )
YIELD STRENGTH
( ƒ ya ) ( ksi )
GROSS AREA ( in 2 )
EFFECTIVE AREA ( A se
)
( in 2 )
B |
0.500 |
65 |
51 |
0.196 |
|
B |
0.625 |
65 |
51 |
0.307 |
|
B |
0.750 |
65 |
51 |
0.442 |
|
B |
0.875 |
65 |
51 |
0.601 |
|
36 |
0.500 |
58 |
36 |
0.196 |
0.142 |
36 |
0.625 |
58 |
36 |
0.307 |
0.226 |
36 |
0.750 |
58 |
36 |
0.442 |
0.334 |
36 |
0.875 |
58 |
36 |
0.601 |
0.462 |
36 |
1.000 |
58 |
36 |
0.785 |
0.606 |
36 |
1.125 |
58 |
36 |
0.994 |
0.763 |
36 |
1.250 |
58 |
36 |
1.227 |
0.969 |
36 |
1.375 |
58 |
36 |
1.485 |
1.160 |
36 |
1.500 |
58 |
36 |
1.767 |
1.410 |
36 |
1.750 |
58 |
36 |
2.405 |
1.900 |
36 |
2.000 |
58 |
36 |
3.142 |
2.500 |
55 |
0.500 |
75 |
55 |
0.196 |
0.142 |
55 |
0.625 |
75 |
55 |
0.307 |
0.226 |
55 |
0.750 |
75 |
55 |
0.442 |
0.334 |
55 |
0.875 |
75 |
55 |
0.601 |
0.462 |
55 |
1.000 |
75 |
55 |
0.785 |
0.606 |
55 |
1.125 |
75 |
55 |
0.994 |
0.763 |
55 |
1.250 |
75 |
55 |
1.227 |
0.969 |
55 |
1.375 |
75 |
55 |
1.485 |
1.160 |
55 |
1.500 |
75 |
55 |
1.767 |
1.410 |
55 |
1.750 |
75 |
55 |
2.405 |
1.900 |
55 |
2.000 |
75 |
55 |
3.142 |
2.500 |
105 |
0.500 |
125 |
105 |
0.196 |
0.142 |
105 |
0.625 |
125 |
105 |
0.307 |
0.226 |
105 |
0.750 |
125 |
105 |
0.442 |
0.334 |
105 |
0.875 |
125 |
105 |
0.601 |
0.462 |
105 |
1.000 |
125 |
105 |
0.785 |
0.606 |
105 |
1.125 |
125 |
105 |
0.994 |
0.763 |
105 |
1.250 |
125 |
105 |
1.227 |
0.969 |
105 |
1.375 |
125 |
105 |
1.485 |
1.160 |
105 |
1.500 |
125 |
105 |
1.767 |
1.410 |
105 |
1.750 |
125 |
105 |
2.405 |
1.900 |
105 |
2.000 |
125 |
105 |
3.142 |
2.500 |
Post-installed mechanical anchors can be qualified for recognition under the International Building Code ( IBC ) via testing per the ICC-ES acceptance criteria AC193 and the ACI test standard ACI 355.2 . Post-installed adhesive anchor systems can be qualified for recognition under the IBC via testing per the ICC-ES acceptance criteria AC308 and the ACI test standard ACI 355.4 .
Data derived from this testing is given in an ICC-ES evaluation report ( ESR ). Precalculated values for N sa are given in ESR design tables . PROFIS Engineering does not calculate N sa per Eq . ( 17.6.1.2 ) for the post-installed anchors in its portfolio . In lieu of performing calculations per Eq . ( 17.6.1.2 ), PROFIS Engineering uses the pre-calculated N sa
-values given in the anchor ESR to define the nominal steel strength in tension . An excerpt from a mechanical anchor ESR showing pre-calculated N sa
-values derived from AC193 / ACI 355.2 testing is referenced to the left .
The PROFIS Engineering adhesive anchor portfolio includes the following anchor elements :
• threaded rods .
• reinforcing bars .
• internally threaded inserts .
• proprietary elements .
An excerpt from an adhesive anchor system ESR showing pre-calculated N sa
- values derived from AC308 / ACI 355.4 testing is referenced to the left . These values are specific to a particular anchor element .
Reference the Equations and Calculations section of the report for more information on N sa
.
Reference the Variables section of the report for more information on the parameters A se , N and ƒ uta
.
145 NORTH AMERICAN PROFIS ENGINEERING ANCHORING TO CONCRETE DESIGN GUIDE — ACI 318-19 Provisions