PROFIS Design Guide - AC 318-19 July 2022 | Page 123

1.0 TENSION

1.4 Side Face Blowout Failure Mode
Calculations N sb
Calculations ACI 318-19 Chapter 17 Provision Comments for PROFIS Engineering single anchor in tension
N sb
17.6.4.1 For a single headed anchor with deep embedment close to an edge ( h ef > 2.5c a1
), the nominal side-face blowout strength , N sb , shall not exceed
N sb
= 160c a1
A brg λ a ƒ ́c ( 17.6.4.1 )
17.6.4.1.1 If c a2 for the single headed anchor is less than 3ca1 , the value of N sb shall be multiplied by the factor ( 1 + c a2
/ c a1 )/ 4 , where 1.0 ≤ c a2
/ c a1 ≤ 3.0 .
PROFIS Engineering calculation for N sb :
N sb
= 160 α corner c a1
A brg λ a ƒ ́c
PROFIS Engineering bearing area values ( A brg ) for the cast-in anchors in its portfolio
MATERIAL SPECIFICATION
AWS D1.1 Type B Headed Stud
" ASTM F1554 Headed Bolt Gr . 36 , Gr . 55 , Gr . 105 "
Diameter ( d 0
) ( in )
Bearing area ( A brg in 2 ) welded headed stud
Bearing area ( A brg in 2 ) square head bolt
Bearing area ( A brg in 2 ) heavy square bolt
Bearing area ( A brg in 2 ) hex head bolt
Bearing area ( A brg in 2 ) heavy hex head bolt
0.500
0.589
0.625
0.920
0.750
0.785
0.875
0.884
0.500
0.464
0.569
0.291
0.467
0.625
0.693
0.822
0.454
0.671
0.750
0.824
1.210
0.654
0.911
0.875
1.121
1.465
0.891
1.188
1.000
1.465
1.855
1.163
1.501
1.125
1.854
2.291
1.472
1.851
1.250
2.228
2.773
1.817
2.237
1.375
2.769
3.300
2.199
2.659
1.500
3.295
3.873
2.617
3.118
1.750
4.144
2.000
5.316
PROFIS Engineering calculates side-face blowout when the anchor effective embedment depth ( h ef
) is greater than 2.5 times the nearest fixed edge ( c a1
). The applied tension load creates lateral bursting stresses at the head of the anchor which cause the concrete to “ blow out ” at the face of the fixed edge . Side-face blowout is a possible failure mode for cast-in anchors and post-installed undercut anchors ; however , PROFIS Engineering does not consider side-face blowout for the HDA-P and HDA-T undercut anchors in its portfolio because it will not be a controlling tension failure mode for these anchors .
When modeling a single anchor in tension , the side-face blowout strength for a single anchor ( N sb
) is calculated , and modified by the factor ( 1 + c a2
/ c a1 )/ 4 if a corner formed by the fixed edge distances c a1 and c a2 exists . PROFIS Engineering designates this factor “ α corner ”. The parameter c a2 corresponds to the fixed edge perpendicular to c a1
.
PROFIS Engineering only performs side-face blowout calculations for the cast-in anchors in its portfolio .
This portfolio is as follows :
• AWS D1.1 Type B headed studs : ( 1 / 2 ” — 7 / 8 ” nominal diameter )
• ASTM F1554 hex head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” — 1-1 / 2 ” nominal diameter )
• ASTM F1554 heavy hex head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” — 2 ” nominal diameter )
• ASTM F1554 square head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” — 1-1 / 2 ” nominal diameter )
• ASTM F1554 heavy square head bolt , Gr . 36 , Gr . 55 , Gr . 105 : ( 1 / 2 ” — 1-1 / 2 ” nominal diameter )
The software uses the minimum spacing and edge distance requirements given in Table 17.9.2 ( a ) for cast-in anchors .
λ a is a modification factor for lightweight concrete . PROFIS Engineering uses the provisions of Sections 17.2.4.1 and 19.2.4 to calculate λ a
.
ƒ ́c corresponds to the concrete compressive strength being modeled . PROFIS Engineering uses the provisions of Section 17.3.1 to calculate ƒ ́c .
Reference the Variables section of the report for more information on the parameters c a1
, c a2 , A brg
, λ a
, ƒ ́c and s .
Reference the Equations section of the report for more information on the parameter N sb
.
Reference the Equations and Calculations section of the report for more information on the parameter α corner
.
123 NORTH AMERICAN PROFIS ENGINEERING ANCHORING TO CONCRETE DESIGN GUIDE — ACI 318-19 Provisions