Product Technical Guides : US-EN Steel Deck Fastening Systems | Page 7

Steel Deck Fastening Systems
Steel Deck Fastener Design and Selection 1.1
2 . Full Scale Diaphragm System Tests
Figure 2 : Small Element Connection Tests
Full scale diaphragm system tests are used to determine the strength and stiffness of a larger steel deck diaphragm assembly directly . The data is analyzed and fit in a predictive model to address varying configurations of base steel , steel deck , specific fastener combinations and spans . These tests are conducted in accordance with the following standards and shown in Figures 3 , 4 and 5 .
• ICC-ES AC43 Acceptance Criteria for Steel Deck Roof and Floor Systems
• AISI S907 Cantilever Test Method for Cold-Formed Steel Diaphragms
• ASTM E455 Standard Test Method for Static Load Testing of Framed Floor or Roof Diaphragm Constructions for Buildings
Figure 3 : ICC-ES AC43 Diaphragm Test Frame Schematics
30 ' -0 "
24 ' -0 "
Figure 4 : AC43 Diaphragm Test Frame Fastening Systems Research Laboratory ( FSRL ), Schaan , Liechtenstein
Hilti , Inc . ( US ) 1-800-879-8000 | www . us . hilti . com I en español 1-800-879-5000 I Hilti ( Canada ) Corp . 1-800-363-4458 I www . hilti . ca I PTG Decking Supplement 2014 5