1.7.1 |
Product Description |
1.7.2 |
Material Specifications |
1.7.3 |
Technical Data |
1.7.4 |
Connector Positioning |
1.7.5 |
Ordering Information |
X-HVB connector |
Connector height , H s in . ( mm ) |
Minimum slab thickness , Y con in . ( mm ) |
Maximum rib height , h r in . ( mm ) w r
/ h r ≥ 1.8 w r
/ h r < 1.8
|
Nominal shear strength 1 , Q n lb ( kN ) |
Allowable shear strength 2 , q lb ( kN ) |
|
X-HVB80 |
3-1 / 8
( 80 )
|
3-11 / 16
( 93 )
|
1-3 / 4
( 45 )
|
1-3 / 4
( 45 )
|
6294
( 28.0 )
|
3147
( 14.0 )
|
X-HVB95 |
3-3 / 4
( 95 )
|
4-1 / 4
( 108 )
|
2-3 / 8
( 60 )
|
2-1 / 4
( 57 )
|
||
X-HVB110 |
4-5 / 16
( 110 )
|
4-13 / 16
( 123 )
|
2-15 / 16
( 75 )
|
2-5 / 8
( 66 )
|
7868 |
3934 |
X-HVB125 |
4-15 / 16
( 125 )
|
5-7 / 16
( 138 )
|
3-1 / 8
( 80 )
|
2-15 / 16
( 75 )
|
( 35.0 ) |
( 17.5 ) |
X-HVB140 |
5-1 / 2
( 140 )
|
6
( 152 )
|
3-1 / 8 ( 80 ) |
3-1 / 8 ( 80 ) |
||
1 Nominal shear strength to be used for designs per AISC-LRFD and unfactored shear resistance per AISC design formulas . | ||||||
2 Allowable shear strength to be used for designs per AISC-ASD . | ||||||
3 Tabulated load values based upon installation in base steel greater than or equal to 5 / 16 ". |