Product Technical Guides : US-EN Steel Deck Fastening Systems | Page 63

Steel Deck Fastening Systems

X-HVB Shear Connector 1.7
1.7.1 Product Description
The Hilti X-HVB Shear Connector is a mechanically attached shear transfer device for use in composite beam construction with steel beams and concrete slabs as an alternate to welded studs .
Product features
• Ductile connections
• Minimal damage to coatings
• Fast and simple installation
• Install in virtually any weather
• No electrical power source required
Guide specification
Shear connector : Shear connectors shall be one piece formed steel with zinc plating in accordance with ASTM B633 SC 1 Type III . Connectors shall be Hilti X-HVB as supplied by Hilti Inc .
Installation : Shear connectors shall be installed using Hilti X-ENP-21 HVB powder-actuated fasteners in accordance with manufacturer ’ s recommendation . ( Note : Do not use X-ENP-19 L15 .)
1.7.1
Product Description
1.7.2
Material Specifications
1.7.3
Technical Data
1.7.4
Connector Positioning
1.7.5
Ordering Information
1.7.2 Material Specification
X-HVB : Carbon Steel with F u = 39,000 psi Zinc plated for corrosion resistance in accordance with ASTM B633 , SC 1 , Type III . Reference Section 2.3.3.1 of Hilti North American Product Technical Guide Volume 1 : Direct Fastening for more information .
1.7.3 Technical Data
Product selection and performance in concrete over metal deck composite floor slabs 3
X-HVB connector
Connector height , H s in . ( mm )
Minimum slab thickness , Y con in . ( mm )
Maximum rib height , h r in . ( mm ) w r
/ h r ≥ 1.8 w r
/ h r < 1.8
Nominal shear strength 1 , Q n lb ( kN )
Allowable shear strength 2 , q lb ( kN )
X-HVB80
3-1 / 8
( 80 )
3-11 / 16
( 93 )
1-3 / 4
( 45 )
1-3 / 4
( 45 )
6294
( 28.0 )
3147
( 14.0 )
X-HVB95
3-3 / 4
( 95 )
4-1 / 4
( 108 )
2-3 / 8
( 60 )
2-1 / 4
( 57 )
X-HVB110
4-5 / 16
( 110 )
4-13 / 16
( 123 )
2-15 / 16
( 75 )
2-5 / 8
( 66 )
7868
3934
X-HVB125
4-15 / 16
( 125 )
5-7 / 16
( 138 )
3-1 / 8
( 80 )
2-15 / 16
( 75 )
( 35.0 )
( 17.5 )
X-HVB140
5-1 / 2
( 140 )
6
( 152 )
3-1 / 8 ( 80 )
3-1 / 8 ( 80 )
1 Nominal shear strength to be used for designs per AISC-LRFD and unfactored shear resistance per AISC design formulas .
2 Allowable shear strength to be used for designs per AISC-ASD .
3 Tabulated load values based upon installation in base steel greater than or equal to 5 / 16 ".
Hilti , Inc . ( US ) 1-800-879-8000 | www . us . hilti . com I en español 1-800-879-5000 I Hilti ( Canada ) Corp . 1-800-363-4458 I www . hilti . ca I PTG Decking Supplement 2014 61