Product Technical Guides : US-EN Post-Installed Rebar Guide | January 2023 | Page 38

Post-Installed Reinforcing Bar Guide
8.0 USEFUL REFERENCE INFORMATION
8.1 ASTM STANDARD REINFORCING BARS
Bar properties 1 Installation parameters 2
Bar size
Nominal diameter [ in ] Nominal area [ in 2 ]
Nominal weight [ lb / ft ]
Bit diameter 3 [ in ]
Adhesive volume per inch of embedment 4
[ cu in ] [ fl oz ]
# 3
0.375
0.11
0.376
1 / 2
0.110
0.061
# 4
0.500
0.20
0.668
5 / 8
0.146
0.081
# 5
0.625
0.31
1.043
3 / 4
0.176
0.098
# 6
0.750
0.44
1.502
7 / 8
0.218
0.121
# 7
0.875
0.60
2.044
1
0.252
0.140
# 8
1.000
0.79
2.670
1-1 / 8
0.299
0.166
# 9
1.128
1.00
3.400
1-3 / 8
0.601
0.333
# 10
1.270
1.27
4.303
1-1 / 2
0.659
0.365
1 Source : ACI 318-19 Appendix B .
2 See Hilti Product Technical Guide for further information .
3 Values shown are typical . Refer to Hilti Instructions for Use .
4 Waste not included .
8.2 CANADIAN REINFORCING BARS
Bar properties 1 Installation parameters 2
Bar size
Nominal diameter [ mm ]
Nominal area [ mm 2 ]
Nominal weight [ kg / m ]
Bit diameter 3 [ mm ]
Adhesive volume per inch of embedment 4
[ mm ] [ mL
10M
11.3
100
0.785
14
86.4
0.0864
15M
16.0
200
1.570
19
121.8
0.1218
20M
19.5
300
2.355
26
296.2
0.2962
25M
25.2
500
3.925
32
418.0
0.4180
30M
29.9
700
5.495
38
630.7
0.6307
1 Source : CSA G30.18 M92 .
2 See Hilti Product Technical Guide for further information .
3 Refer to Hilti Instructions for Use .
4 Waste not included .
8.3 COMMON GRADES OF REINFORCING STEEL
Specification
Minimum specified yield strength , f ya
Minimum specified ultimate strength , f uta
ASTM A615 Grade 40
ASTM A615 Grade 60
ASTM A706 Grade 60
CAN / CSA-G30.18 Gr . 400
psi
40,000
60,000
( MPa )
( 276 )
( 414 )
psi
60,000
80,000
( MPa )
( 414 )
( 620 )
psi
60,000
80,000
( MPa )
( 414 )
( 550 )
psi
58,000
78,300
( MPa )
( 400 )
( 540 )
36 November 2022