3.0 MODULAR SUPPORT SYSTEM
3.2.3 MT SYSTEM CONNECTORS
MT-C-GSP T OC
Description
Gusset plate for T-shaped connections with MT-70 and MT-80 girders .
Material Specifications
Standard 1 Grade 1 F y , ksi ( MPa ) F u
, ksi ( MPa )
GB / T 1591 Q355 B 51.49 ( 355 ) 68.17 ( 470 )
1 . Mechanical properties of GB / T 1591 Grade Q355 B meet or exceed the mechanical properties of ASTM A1011 SS Grade 50 .
Corrosion Protection
Hot-Dipped Galvanized ( HDG )
����� “) �
���
����� “)
���
������ “)
MT-C-GSP T OC
Ordering Information
Description
Weight Per Piece lbs ( kg )
Quantity Piece ( s )
Item No .
MT-C-GSP T OC 0.95 ( 0.43 ) 10 2272074
���
������ “)
��� ������� “)
mm ( in )
Figure 48 - MT Girder Connection
Table 153 - Allowable Strength Design ( ASD ) Load Data 1 , 2 , 3 , 4
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M y ft lb ( kN m )
M z ft lb ( kN m )
10,250
1,300
1,575
600
280
( 45.60 )
( 5.80 )
( 7.01 )
( 0.82 )
( 0.38 )
1 . Minimum safety factor , Ω , for tabulated values is 2.2 . 2 . Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design
( LRFD ) values . 3 . Tabulated values are based on plates being installed in pairs . 4 . See Figure 48 .
Table 154 - Limit State Design ( LSD ) Load Data 1 , 2 , 3
A . MT-70 B . MT-70 / 80 ( long side )
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M y ft lb ( kN m )
M z ft lb ( kN m )
13,375
1,955
2,365
855
420
( 59.50 )
( 8.71 )
( 10.54 )
( 1.16 )
( 0.57 )
1 . Maximum resistance factor , ϕ , for tabulated values is 0.65 . 2 . Tabulated values are based on plates being installed in pairs . 3 . See Figure 48 .
Figure 49 - MT Girder Connection
Table 155 - Allowable Strength Design ( ASD ) Load Data 1 , 2 , 3 , 4
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M y ft lb ( kN m )
M z ft lb ( kN m )
9,440
1,660
3,170
905
530
( 42.00 )
( 7.39 )
( 14.11 )
( 1.23 )
( 0.72 )
1 . Minimum safety factor , Ω , for tabulated values is 2.0 . 2 . Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design
( LRFD ) values . 3 . Tabulated values are based on plates being installed in pairs . 4 . See Figure 49 .
Table 156 - Limit State Design ( LSD ) Load Data 1 , 2 , 3
A . MT-70 B . MT-70 / 80 ( long side )
2023
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M y ft lb ( kN m )
M z ft lb ( kN m )
13,400
2,495
4,415
1,280
800
( 59.62 )
( 11.10 )
( 19.64 )
( 1.74 )
( 1.09 )
1 . Maximum resistance factor , ϕ , for tabulated values is 0.7 . 2 . Tabulated values are based on plates being installed in pairs . 3 . See Figure 49 .